1, responsible for the installation, repair and maintenance of high and low voltage lines, motors and electrical equipment in the company and workshop, and the responsibilities of property management.
2. Seriously study and master advanced power technology, and be familiar with the use, structure, principle, performance, operation and maintenance of power and electrical equipment within its jurisdiction.
3, strictly abide by the ministerial circuit technical regulations and safety regulations, to ensure safe power supply, to ensure the normal operation of electrical equipment.
4, often go to the scene, patrol and check the status of electrical equipment and its safety protection, listen to the opinions of the operators, it is forbidden to sleep in class.
5. Fill in the records of electrical equipment overhaul (maintenance items, contents, parts, replacement parts, date, working hours, spare parts and material consumption, etc.). ) and accumulate raw data.
6. According to the debugging requirements, participate in the major and medium repair debugging acceptance of the repaired equipment.
7, master the use of tools, measuring tools, instruments and carefully keep, save the use of spare parts, materials, oil. Do a good job in civilized production and make handover records.
Safety responsibility of electricians II
A, all electrical wiring, power supply and distribution equipment, must be reasonable design, correct installation, according to the provisions of the use.
Second, the installation and wiring of electrical equipment must be carried out by full-time electricians, and no one is allowed to connect or pull wires without permission.
Three, the contact with the use of wires, switches, insurance, bolts, lighting, electric furnace, motor and other electrical equipment workers, to strengthen the safety of electricity knowledge education, to avoid electric shock and fire accidents caused by improper use.
Four, the electrical equipment, should strengthen the inspection and maintenance, to prevent their own fire and explosion.
Five, to check regularly, replace the electrical circuit, to prevent the circuit corrosion and aging caused by leakage short circuit.
Six, flammable and explosive places should be in accordance with the provisions, choose explosion-proof electrical appliances, switches and lamps and lanterns, line requirements laid in protective casing.
Seven, temporary line should be approved by the department head, in accordance with the requirements, such as the designated persons responsible for the immediate removal after use.
Eight, according to the provisions set lightning protection device and electrostatic grounding device, and regular inspection, make it meet the safety requirements.
Nine, the power room should be tight, to prevent short circuit caused by small animals, and to prevent leakage.
Ten, electrical fire, should first cut off the power supply, and then put out the fire. Foam extinguisher is strictly prohibited when fighting. Dry powder fire extinguisher and carbon dioxide fire extinguisher can be used.
11. When electrical maintenance is carried out, the power must be cut off, and a sign "No switching on when someone is operating" is hung on the handle of the power switch. Power failure, discharge, electricity inspection and maintenance must be supervised by the person in charge of the operation, otherwise the operation may not be carried out. Under normal circumstances, live working is prohibited. If live maintenance is needed, it should be approved by the factory leaders and reliable safety measures should be taken. Maintenance personnel and guardians must be electricians with practical experience.
Twelve, electrical workers, should wear labor protection articles in accordance with the provisions and the correct use of electrical tools and fire equipment that meet the safety requirements;
Thirteen, electrical operators should strictly implement the operation ticket, work ticket system, work permit system, work monitoring system, work interruption, transfer and termination system;
Fourteen, the personnel on duty should patrol the running electrical equipment during work, and monitor the operation of the equipment;
15. Live working on electrical equipment and power supply lines is not allowed. Before maintenance, it must be confirmed whether all equipment is powered off. After power failure, lock the power switch and hang signs such as "No switching, someone is working";
Sixteen, approved must be charged maintenance, reliable safety measures should be taken, and by people with practical experience as guardians, otherwise no work;
17. The erection of temporary lines shall strictly abide by the relevant provisions of the Application Form for Temporary Wiring Devices. "A 380-volt rubber temporary line with good insulation is suspended on the ground: not less than 2.5 meters indoors and not less than 3.5 meters outdoors;
Eighteen, replace the fuse, fuse should be selected in strict accordance with the provisions, and other metal wires should not be used at will.
- Previous article:What about Shanghai Lei Fang Property Management Co., Ltd.?
- Next article:Where is the address of Daping Village?
- Related articles
- [Urgent] Where can I watch the sunrise by the Nantong River?
- What about Wuxi Henglizhou Materials Trading Co., Ltd.?
- How to get to Shijiazhuang North Station from Shuxiang Garden?
- How do the "deadly enemies" of property and owners get along gracefully?
- Can I collect property fees without signing a property contract?
- Is there a room book in Gu 'an Hong Zhong New District?
- What is the telephone number of Xining COFCO Gold Seal Marketing Center?
- Is it reasonable that owners without parking spaces are not allowed to drive into the community?
- What about Quanzhou Sizhi Culture Communication Co., Ltd.?
- What's next to Yalong Lanting in Caohu Lake?