Haydn wall-hung boiler does not work.
Operating steps of wall-hung boiler
The first step of ignition:
First, press the reset key to start the machine, unscrew the black water replenishing valve at the bottom of the chassis to the left, and close the black water replenishing valve with the water replenishing pressure ranging from 0.0bar to 1.0~2.0bar (usually 1.3bar). Then try to put air into the radiator and observe the pressure. The wall-hung boiler can start to work normally without pressure relief; If the pressure is released, please continue to open the water replenishing valve to replenish water, and close the water replenishing valve after the pressure is normal.
Second, when the pressure is within the normal range, press the function key to take a bath and press the function key twice to keep warm. If you need to adjust the temperature manually, press the up and down keys directly. To turn off the power, press the reset button.
Conversion between floor heating and radiator
First, when the wall-hung boiler is in normal heating or bathing state, open the operation panel, find the shortcut function key behind the operation panel and press it for 5 seconds, and the parameter CL will be displayed on the LCD screen. Then use the upper and lower temperature keys to find the parameter CS, and press the function key once after finding it to enter the conversion state. Go in and show that 0 1 is a radiator. Install the upper and lower temperature keys to switch between the floor heating and the radiator, and press the function key to push it out after the conversion is completed. Press the up and down temperature keys to adjust to CL, and then press the shortcut function key for 5 seconds to display the working temperature.
- Related articles
- What about Shenzhen Shiyan Emerald Apartment Property Management Co., Ltd.?
- What is the charging standard of property fees for rural resettlement communities in Shaoxing in 2020? Which department approved the collection standard of property fees?
- How about Junhao (Shandong) Property Management Co., Ltd.?
- Why is it so cheap to visit Beijing Longhu?
- Department work plan for the new semester 20 18
- Will the second phase of Zhangmutou Huadu Garden be rebuilt?
- Guizhou Railway Vocational School
- 20 10 12 Hangzhou education bureau and its affiliated institutions recruit staff.
- Does the property have the right to stop gas if the owner does not pay the heating fee?
- What is the telephone number of marketing center of Chifeng Wantong Commercial Plaza?