What problems should be paid attention to in terms of fire protection and property (load) when setting up an ice rink of about 1000 square meters on the seventh floor of the shopping center? Please en
As the roller skating rink should belong to the standard of singing and dancing entertainment, according to the requirements of the Code for Fire Protection Design of High-rise Civil Buildings, such places should be set on the first floor or the second and third floors of the building, but there are many requirements when setting other floors, as follows:
1. The area of each hall should not be greater than 200m2, and the area of 1000m2 should be divided into at least five independent rooms.
2, more than 50 square meters of room to ensure at least two exits.
3. Automatic fire alarm system and automatic sprinkler system shall be set up.
4. Smoke exhaust facilities should be set up (mechanical smoke exhaust facilities must be installed without external windows).
5. Luminous evacuation signs should be set.
In addition, to open such a place in a shopping mall, a separate fire zone should be formed, and the place should have at least two evacuation stairs. The number of people in such places is calculated by one person every two square meters, and the evacuation width should be at least 5 meters. If the two evacuation stairs cannot reach the evacuation width of 5 meters, they should be increased.
The load problem you mentioned is generally taken into account in the design of shopping malls. Shopping malls with general frame structure should be able to bear the weight of skating rink equipment and personnel.
Do you mean you want to open a real skating rink? Then you have to mainly consider the bearing capacity of the building and consult the drawings with professionals. In addition, the area of each hall and room cannot be limited in terms of fire protection.
- Previous article:Where is Qujing CIMC Kirin International Center?
- Next article:How many years is the property right of Qinhuangdao MCC Dexian Mansion?
- Related articles
- How to take the subway from Chengdu to Huayang, Watermark City?
- What about Qingdao Shengtai Property Service Co., Ltd.?
- How about North Shore 1292 Commercial Plaza? OK or not? Is it worth buying?
- Is there telecom broadband in Kunshan Shimao East Bund?
- How about Shuimogou Nanhu Tianheju Community?
- Is there a future for 20 19 wallpaper industry?
- Where is Ruiwan House in Shenzhen Overseas Chinese Town?
- How to locate the property?
- Can I apply for a pre-sale certificate without a property pre-management contract? The premise is that our company independently establishes a property company. Waiting online.
- Is the Poly Jin Quan Community in the Asian Games Village an upscale community?