Job Recruitment Website - Property management - Land rent theory and location theory included in Haidilao site selection.

Land rent theory and location theory included in Haidilao site selection.

1, the height of the floor is generally required to be above 3800mm (the height from the ground to the beam), and the minimum should not be less than 3500 mm. Generally, the ceiling of our equipment needs to be 800mm- 1000mm under the beam, and the final ceiling clear height should not be less than 2500 mm

2, the use area is generally not less than 1600 square meters.

3. Do not consider that the residential building is under or close to the residential building. The general EIA requirements are: the distance between the residential building and the main building is not less than 9 meters, and the outdoor equipment is placed not less than 20 meters away from the residential building.

4. Fire-fighting requirements: Generally, there should be at least one fire-fighting evacuation passage within 30 meters of any point in the leased area, and the farthest compartment should not be more than 25 meters away from the evacuation passage. The leased area required by our company should not be less than 2 evacuation routes. Fire partition requires that the height of the main building is generally not more than 24 meters, and the fire partition is set at 2500 square meters. If the height of the main building is generally more than 24 meters, the fire partition can be set at 2000 square meters. Under normal circumstances, if the building mainly has a fire zone, it needs the written consent of the property right unit to transform the original fire zone in compliance with fire regulations.

5. According to Article 6 of China's Measures for the Administration of Urban Housing Leasing, the following houses shall not be rented:

1) There is no legal house ownership certificate.

2) The judicial organ or administrative organ decides to seal up or restrict the real estate rights in other forms.

3)*** Some houses have not been approved by others.

4) The ownership is disputed.

5) illegal construction.

6) Failing to meet the safety standards.

7) It has been mortgaged without the consent of the mortgagor.

8) Not conforming to the relevant regulations of public security, environment, health and other major departments.

9) Other houses that are not allowed to be rented according to laws, regulations and rules.

Second, the engineering requirements

1. power requirements: the general power is 230-260 watts/square meter, and the total amount is basically between 450 kilowatts and 550 kilowatts according to the area needs.

2. Gas generally needs 70m? More than/hour, the flow rate of each gas stove on our dining table is 0.35m? /hour, the medium pressure furnace in the back kitchen is generally 4-8m? /hour, the tea stove is generally at 23m? /hour

3. The water demand is generally 80 tons/day.

In principle, we install the air conditioner ourselves. When the original air conditioner is dismantled, we need a platform (about 100 square meter) to place the outdoor air conditioner. If the original property can meet our air conditioning needs (the cooling capacity is 400 watts per square meter, and the opening hours are controlled by us), we can use the original property air conditioner.

We installed the HVAC and exhaust system ourselves, and dismantled the original system.

Third, the business circle requirements

1, the general population movement requires that the population within 3 kilometers should be more than 200,000, and there are large-scale brand businesses and shopping centers (such as Wal-Mart, Hualian Shopping Center and Jiamao Shopping Center). ) around1-2km, or local famous dining streets and shopping centers.