Job Recruitment Website - Property management company - Construction standard of electric vehicle parking shed in residential area

Construction standard of electric vehicle parking shed in residential area

1, the new electric vehicle parking shed should meet the safety requirements of fire protection, traffic and structure.

2. The height of the parking shed shall not exceed 2.5 meters, and it shall not be enclosed around.

3, distribution box should not be installed in the carport.

4. The charging equipment installed in the charging shed should be installed on the ground or on the lateral support supported by the carport.

5. Charging equipment shall not be installed within the range of 1.6m on both sides of the open charging shed, and fire extinguishing devices such as fire extinguishers shall be placed.

6. For a row of charging sheds, the roof on the side where the charging equipment is installed should be in a lower position, and the eaves of the roof should extend to the charging equipment at a distance of not less than1.2m..

7. Double-row carport: Whether it is a herringbone roof with high, medium and low eaves or a V-shaped roof with low, medium and high eaves, its charging equipment should be installed in the middle. If it is really necessary to install on both sides, the cornice on the roof should be extended to the distance of charging equipment not less than1.2m..