Job Recruitment Website - Property management company - Daikin 16 Central Air Conditioning Parameters

Daikin 16 Central Air Conditioning Parameters

Power?Supply?

Single-phase, 220v, 50hz

refrigerating output

kilowatt

2.8

3.6

4.5

5.6

7. 1

9.0

heat capacity

3.2

4.0

5.0

6.3

8.0

10.0

Consume electricity

w

90/75

97/82

106/90

1 18/ 10 1

173/ 159

Size (height× width× depth)

millimetre

230×840×840

288×840×840

Air output

Cubic meters per minute

12/9.5

13/9.5

15/ 10

16.5/ 13

26/ 19

Running sound

Decibel (Ampere)

29/26

30/26

3 1/26

32/27

37/3 1

weight

kilogram

25

30

Art cover

model

BYCP 125DW 1C

measure

45×950×950

weight

5.5

Piping (mm)

Liquid pipeline/

trachea

Diameter 6.4/ diameter 12.7

Diameter 9.5/ diameter 15.9

drainpipe

VP25 (outer diameter 25× inner diameter 32)

Specification parameters of household VRV system:

model

FJNP28MMVC

FJNP45MMVC

FJNP56MMVC

FJNP7 1MMVC

Power?Supply?

Single-phase, 220v, 50hz

refrigerating output

kilowatt

2.8

4.5

5.6

7. 1

heat capacity

3.2

5.0

6.3

8.0

Consume electricity

w

49/49

90/90

1 10/ 1 10

Size (height× width× depth)

millimetre

6 10×930×220

6 10× 1070×220

6 10× 1350×220

Air output

Cubic meters per minute

7/6

1 1/8.5

14/ 1 1

16/ 12

Running sound

Decibel (Ampere)

35/32

38/33

39/34

40/35

weight

kilogram

19

23

27

Piping (mm)

Liquid pipeline/

trachea

Diameter 6.4/ diameter 12.7

Diameter 9.5/ diameter 15.9

drainpipe

2 1, outer diameter (vinyl chloride pipe)

Specification parameters of household VRV system:

model

FJAP22MMVC

FJAP28MMVC

FJAP36MMVC

Power?Supply?

Single-phase, 220v, 50hz

refrigerating output

kilowatt

2.2

2.8

3.6

heat capacity

2.5

3.2

4.0

Consume electricity

w

16/24

22/27

27/32

Size (height× width× depth)

millimetre

290×795×230

Air output

Cubic meters per minute

7.5/4.5

8.0/5.0

9.0/5.5

Running Tone (Strong/Weak)

Decibel (Ampere)

35/29

36/29

37/29

weight

kilogram

1 1

Piping (mm)

Liquid pipeline/

trachea

Diameter 6.4/ diameter 12.7

drainpipe

Pvc 18 (inner diameter 13, outer diameter 18)

Note: Capability determination conditions:

The indoor unit capacity above 1. indicates the refrigeration condition: indoor return air temperature is 27℃DB, 19℃WB, outdoor temperature is 35℃DB and 24℃WB. The refrigerant pipeline is 5m long (horizontal).

2. The above indoor unit capacity indicates the heating condition: indoor return air temperature is 20℃DB, outdoor temperature is 7℃ DB, and 6℃ WB. The length of refrigerant pipeline is 5m (horizontal).