Job Recruitment Website - Property management company - The electrothermal film thermostat is broken.

The electrothermal film thermostat is broken.

◆ System composition. The safe electrothermal film heating system consists of electrothermal film, connecting wire, connecting card, temperature controller, thermal insulation material and waterproof material. The whole system is hidden under the ground except that the thermostat is installed on the indoor wall. It is very safe to use: the electric heating film is waterproof and flame retardant, so there is no need to worry about water leakage and electric shock, and it will not cause burns, explosions and spontaneous combustion. Parallel heating, double induction temperature control, leakage protection skills, quadruple protection. Palmer's electrothermal film heating system belongs to low-temperature radiation heating, and the nominal temperature of electrothermal film during operation is within 50℃. The system has a temperature control device, and the temperature controller will actively control the whole system. When the indoor temperature meets the user's requirements, all electric heating film systems will stop running, and when the indoor temperature is lower than the user's requirements, all electric heating film systems will start running on their own initiative. ◆ When the heating system runs for the first time, the heating time will be longer and more electricity will be consumed, which does not mean that your heating system has high operating cost. Only when the indoor temperature is in balance with the set temperature and enters the active control state can the actual operating cost be reflected. When the Palmer electrothermal film heating system supplied by Shikang Technology is heated for the first time or not started for a long time, the thermostat of the system should be set at the low temperature range of 10℃ for 2-3 hours for a short time, and then adjusted to the abnormal temperature value. If your environment is a new house completed that year, the overall occupancy rate and structural moisture content will cause heat loss. The electricity consumption in the first heating period will be relatively high, and it will take about 3-5 days for the indoor temperature to reach 18℃ and above. Starting from the second heating season, the system will reach the abnormal operating cost. When running the heating system for the first time, it is recommended to ask professionals to help debug it. ◆ Operating cost Palmer heating system provided by Shikang Technology is an energy-saving heating product that truly realizes household, room and time-sharing heating. Due to different building structures, different building orientations, different heat transfer between households, different insulation consequences of envelope structures, different occupancy rates and different outdoor temperatures in that year, the deviation of utilization costs will be caused. Users are advised to use temperature reasonably, save energy and reduce operating costs. ? The exterior wall of the side apartment is a cold gable, and its heat loss is definitely greater than that of the next-door apartment. In some cases, the design power of electrothermal plastic film is also slightly higher, and the power consumption will definitely increase. ? The thermal insulation function of the building itself is directly related to Palmer electric heating system, and it must be constructed according to the design node diagram. The better the overall thermal insulation function, the smaller the environmental temperature difference and the lower the power consumption. ? The quality grade of thermal insulation materials and doors and windows must meet the design requirements. After planning, it can be known that the heat consumption through doors and windows accounts for more than 50% of the total heat consumption of the building. The better the insulation and sealing of doors and windows, the less heat loss, so doors and windows are the focus of energy saving. ? If the whole building is heated by electric heating film, if the whole energy-saving heating design is followed, when a household's adjacent room does not start heating, its heat consumption will increase because the household will transfer heat to the unheated adjacent room, which will lead to the situation that the operating cost is too high or the temperature is not up to standard, which is abnormal. Of course, for indoor wall construction with thermal insulation method, the severity of this situation will be appropriately reduced. ? The temperature of electro-plastic film is warmer, especially in the process of Palmer's electro-plastic film heating system. Indoor doors and windows are not easy to open frequently, so try to reduce the number of opening doors and reduce heat energy consumption, so as not to affect the heating consequences and increase operating costs. ? Improper use of temperature controller and frequent switching make Palmer electrothermal film heating system change its working state frequently, and the electricity consumption will increase? It is suggested to use peak-valley watt-hour meter, because the peak of electricity consumption for electric heating is at the low valley at night, which will enjoy the preferential price of electricity and save more operating expenses. ? In the new house that was occupied in that year, because there was a small amount of water in the wall structure, filling layer and insulation layer, the occupancy situation was different and the heat transfer ratio between households was different, which would lead to high heat consumption. The electricity consumption in the first heating period will be slightly higher, and the cost of the second heating period will naturally decrease. ? In order to save more energy, it is suggested to install push-pull partition doors and thermal insulation curtains between balconies, and close them at night. ◆ Ground materials? Imported geothermal floor, the quality reaches the European ENPR 13329 standard? Does the domestic geothermal floor meet the national GB/T 1802-2000 standard? Lock the floor (not easy to deform)? Special note: In order to protect the consequences of your electric heating system and make it more economical and comfortable for you to use, please pay attention to the following points: when laying the floor directly on the electric heating film, you should choose geothermal floor, and its thickness should be controlled between 8-12 mm. Do not choose composite floor that is too thick or too wide, which will easily affect heat dissipation. The thickness should be below 1㎝ and the width should be around 15㎝; The floor mat should be laid under the electrothermal film (for example, a floor mat with a metal surface, which is laid down) and above the heat insulation layer (extruded board). In order to make heating more comfortable and reduce the starting times of electric heating system, the method of laying wooden floor directly on electric heating film is not advocated, but the method of laying wooden floor after making cement cushion on the film is adopted. ? When using electric heating film to keep warm in humid environment (such as toilet or bathroom). ), it is necessary to waterproof the electric heating film to avoid damage caused by construction. ? Protect the thermostat with waterproof tape during decoration to avoid the failure of holding due to contact with water, dust and various oil stains. ? It is forbidden to cover objects in the heating area of electric heating film. It is recommended to choose furniture with legs to ensure the filling and dispersion of heat. ? It is forbidden to drill holes and nail in the laying area of electric heating film, which may damage the electric heating film. ? If the toilet is equipped with other heating methods, it must be opened at the designated position when heating, because it is the auxiliary heating equipment of Palmer's electrothermal film heating system. If it is not turned on, the actual heating power will drop, which will affect the heating consequences and even increase the operating cost. ? If the occupancy rate is low, it is suggested that customers do internal insulation treatment for indoor walls during decoration, which can reduce the operating costs caused by low occupancy rate. ◆ Precautions? Please do not modify the original building structure, doors and windows, ground decoration, etc. If it needs to be modified, the property must be informed in advance, so that the design of Palmer electrothermal film heating system can be modified accordingly. If you don't tell us or modify the building decoration practices after the system installation, our company will not be responsible for the heating consequences. ? Temperature controller: When Palmer electric heating plastic film is heated to the required temperature under abnormal conditions, the system is at full load, and the required temperature is slightly different according to different floor materials. Usually laid directly under the composite floor, the temperature rises quickly, and the nominal temperature reaches 18℃ for about 30 minutes. If laid under the mortar layer, it takes about 90 minutes for the nominal temperature of the 2-3 cm mortar layer to reach 18℃. Therefore, it is suggested that it is best not to switch on and off the thermostat power frequently in festivals, so that the thermostat can actively adjust the indoor temperature to save energy; ? Please do not block, shake or change the installation position of the thermostat. There should be no heat source around the thermostat to avoid damage or temperature control error. ? When the electrothermal film heats up, it is suggested that you set the thermostat at your required temperature according to the indoor temperature. Don't mistakenly think that when setting a high temperature value, the indoor temperature will rise rapidly, which will only increase the operating cost. ? Please don't turn off the thermostat when you separate a room or in an uninhabited room. You may adjust the temperature to 12- 15 degrees or the corresponding gear, because the heat consumption cannot be replenished in time after the system is turned off, and the temperature rises slowly when it is turned on again, which consumes a lot of electricity and does not save energy. ? The Palmer electrothermal film heating system provided by Shikang Energy Saving Technology is warmer than others. Try to reduce the heat loss caused by the high-speed flow of cold air by opening doors and windows so as not to affect the heating consequences. ? The thermostat is a precise electronic component. Please don't shake it casually to avoid damage. ◆ Common fault diagnosis? Failure of thermostat temperature control: Check whether the thermostat is blocked or there are cold and heat sources nearby. ? Cause of failure: Check whether the thermostat switch or power supply is turned on? No matter what temperature the thermostat is set to, the light is always green-it doesn't work. Cause of failure: Ground temperature probe failure or temperature controller control part failure? No matter what temperature the thermostat is set to, the starting light is always red-working. Cause of failure: failure of the thermostat control part? No matter what temperature the thermostat is adjusted to, the electric heating system usually works. Cause of failure: failure of the thermostat control part? Causes of failure of electric heating plastic film: whether there is power failure, whether the distribution line is turned off artificially and whether the thermostat is turned off. ◆ Refer to the operating instructions of the thermostat with corresponding specifications and models. ◆ Warranty period: the electric heating film installed by Shikang Energy Saving Company is guaranteed for ten years from the date when the product is qualified for debugging, and the temperature control switch is guaranteed for two years from the date when the product is qualified for debugging. During the warranty period, the company will provide free maintenance for failures caused by product quality problems on the premise that customers use them accurately according to the specifications. The specific content is subject to the warranty card. The above is the description of the housing utilization we provide for you. Please contact Shikang Energy Saving Technology Co., Ltd. or property management company if there are any unfinished matters. Thank you again for using Shikang energy-saving technology to provide you with Palme electric heating system, and look forward to more opportunities to provide you and your friends with wholehearted service. 5, tcxtleksan is very good, you might as well try it:) hnmxvputwq6 177568378