What is the decoration standard of the physical examination center?
First, the basic ideas and general ideas
1. The physical examination center is also a place of consumption and property.
According to the principle of market economy, it is also a consumption behavior for people to go to the physical examination center. The high consumption of physical examination is to remind people to do enough physical exercise. Physical examination center, like other buildings, is also a kind of property and should be operated according to the laws of property management.
2. Cultural design and CI design
Under the principle of universality of physical examination center, its particularity is highlighted. It embodies simplicity, high efficiency, humanization and environmental protection. 3. Barrier-free design
Disabled toilets should be set up independently, with the largest dedicated space. Stairs should be equipped with double conductor handrails for the convenience of adults and children. Stairs should be started and stopped by the blind. The impact protection of wheelchair and stretcher should be considered for elevator doors and cars. 4. Lighting equipment
For consumers, the lights should not be too bright or too dark. _ Avoid lighting lamps. It is best to choose a light color with good color rendering, and the color is slightly warmer. 5. Water supply and sewage treatment
From the aspects of system selection, pipeline layout, pipelines and accessories, epidemic prevention requirements, etc., we should make overall consideration to ensure water quality and prevent cross infection. Use a non-manual switch. Classified collection, treatment and reuse of sewage. 6. Management intelligence system
The standard version includes: consultation, appointment, billing, inspection, inquiry, cost accounting, filing and personnel management, nurse station management and other modules. Require a reasonable placement; The color of the facility is in harmony with the surrounding environment; Hide as far as you can. 7. Intelligent building control
Including air conditioning, computer station, local area network, multimedia, general control room, elevator, five gas, telephone intercom, integrated wiring, safety monitoring, fire protection, communication, cable TV, garbage and water treatment system, etc. It is required that the decoration style should be coordinated with the overall space; The decorative materials are in harmony with the original facilities, and there is no obvious decorative feeling; If the exposed part of the facility is quite different from the overall environment in terms of shape, color and texture, and it really needs to be replaced but cannot be hidden, it should be adjusted with the supplier before installation to avoid losses; The exposed intersection point of the equipment outside the decorative surface should form a rhythm with the shape and lines of the decorative veneer, and at the same time ensure that the function of the equipment is not affected. 8. Professional logo design
Words, patterns and color signs should be eye-catching, clear and definite. Different departments can use different colors. Colors should be elegant and harmonious. Pay attention to the comparison of Chinese and foreign languages, styles, positions, colors, shapes, textures and decorations. There are three types.
Outdoor category: first, the guiding signs and architectural signs of individual buildings in the whole area of the medical examination center; The second is road guidance; The third is the positioning of the service facilities of the medical examination center.
Floor type: 1. General indoor functional plan and functional plan of each floor; The second is the identification required by national standards (fire exits, entrances and exits, etc.). ). Department unit category: First, the door and window logo of the physical examination center; The second is the sign of public service facilities; The third is the special symbol stipulated by the industry.
Second, the consideration of different functional spaces.
1. Parking lot
The ground parking lot should have special taxi waiting space and access streamline. 2. Consultation reservation hall
It is the intersection of all kinds of streamline in the physical examination center and the most crowded public place. It is necessary to separate male guests from female guests and distinguish between traffic and detention space-it is convenient to organize and guide the flow of people. Natural lighting and ventilation, and in the form of skylight.
Consultation, appointment and payment desk should be 750mm, and standing service should be changed to sitting service. Set up a large screen to display all kinds of related information. The business desk should be equipped with a sufficient number of row chairs, which should be changed from hard to soft, and the row chairs should be changed into sofas.
3. Corridor
Waiting loungers should be set at the door of each department, and the chairs should be fixed and soft (detachable and washable). And equipped with a trash can.
3. Public toilets
On the premise of solving the problem of line of sight interference, it is advocated that there is no door in the bathroom. Set up a special cleaning room. The urinal should avoid the previous step. The toilet is comfortable to sit on, but it needs to solve the problem of taking paper at one time (it is recommended to use an automatic pad changer); Squat down, make the toilet and the ground on the same side, and set up infrared induction flushing. Install handrails, hooks and small shelves on the partition of toilet seat, and the partition should have a certain height. Faucets, urinals and urinals should have induction. Hand dryer is suitable for wiping toilet paper. Signboards should be set up in conspicuous places to tell you when to wash your hands.
Walls can be made of smooth stones to minimize wide seams. Special caulking agent should be used. Tempered glass painted on the back can also be used. The ground can be made of stone or floor tiles, preferably 500×500mm, and large blocks should not be drained. The partition can be made of MAX plate and assembled on site.
4.CT and x-ray room
It is very important that this kind of space meets the requirements of radiation protection. According to the lead equivalent of the maintenance structure provided by the equipment manufacturer, the lead plate is selected to be compounded on the back of the aluminum plate. All walls except doors and lead windows can be installed with elegant aluminum plate overhead. Pay attention to the protection loopholes caused by fixing screw holes, and it is best to stick them. Lead plate doors should be decorated with rubber plates, and there is generally no radiation protection requirement in the vertical direction. Aluminum gusset ceiling can be used.
5. Inspection department
Each examination room is divided into independent rooms and the process is reasonable, and the net area of each examination room is not less than 8_. When a multi-person examination room is set up, the clear distance between examination beds should be not less than 2m, and soft partitions must be set up. Ophthalmology should set up a special darkroom. Warm and bright color, smallpox is not easy to have a variety of shapes, using mineral wool board or gypsum board. Set the cleaning pool according to the needs of the department. It is wise to open the window backwards. Meet the needs of ventilation, safety protection and convenient cleaning.
8. Medical furniture and environmental protection decorative materials
The height of the seat should be 90 ~ 420 mm, and the furniture materials should be durable, pollution-resistant and chemical-resistant, such as Dutch Si Qian board. Environmental protection latex paint, aluminum anti-static floor, imported rubber floor and other decorative materials. Department-rubber floor. Bathroom, dressing room, computer room, archive room, storage room, smoking room, boiling water room, fire escape-floor tile. Hall, corridor-imitation wood grain (tile, stone) plastic floor. Executive office-office blanket. Scientific research and testing-anti-static floor and anti-corrosion floor tiles. Ceiling: reservation hall-modeling gypsum board; Corridor-gypsum board (aluminum board, mineral wool board); Department-public toilet-aluminum gusset plate; . Disinfection color latex paint for wall surface; Bathroom wall: All external corners of ceramic tiles shall be provided with anti-collision corner protectors. The wall of the smoking room-tempered glass (transparent glass)
Third, the professional requirements
1. Professional requirements
No dust, no dust, corrosion resistance, moisture resistance, mildew resistance, fire prevention and easy cleaning. The color should be mild and elegant, which can be light green or light yellow. Green and blood red are complementary colors, which can reduce the eye fatigue of medical staff and have a calming effect on the psychology of medical examiners. Yellow has a sense of balance and depression, avoiding the convergence with the green wall.
Interior design and decoration construction should be based on professional requirements for electrical design, clean air conditioning design and terminal design. 3. Hexahedral requirements
Ground. Should be flat, using environmental protection, antibacterial, wear-resistant, anti-slip, corrosion-resistant, easy to clean, easy to remove dust and not crack decorative materials, pay attention to the rubber floor or artificial stone floor, and make it into a whole internal corner treatment with the ground. Walls. Lightweight steel keel gypsum board partition wall should be adopted.
The wall can be tilted inward by 3 degrees, which can not only reduce dust accumulation, but also make the angle of light reflection beneficial to the operation of medical staff. The skirting board should be recessed into the wall 1cm and integrated with the ground, with a fillet radius of 40 mm ..
Smallpox. Need to arrange the installation of high-efficiency filter air supply outlet, lighting lamp, fire extinguisher, etc. , and all kinds of pipelines should be hidden in the ceiling. Can also be used aluminum gusset plate, mineral wool board ceiling.
Doors and windows. Hollow double-layer windows with dust-proof seal and good sound insulation effect should be adopted, and special windows made of stainless steel or plastic steel can be selected. The door shall be an automatic induction type electric color steel sliding door with a delay device.
- Previous article:What sunshine garages are there in Daqing?
- Next article:How to make money by buying reits? Is there any risk?
- Related articles
- What is the employee evaluation of Beijing Higher Education Jinma Property Management Co., Ltd.?
- What about Wuhan Rongyuan Real Estate Development Co., Ltd.?
- Where is Zibo Xuhui Yinsheng Taihui Shengxinyuan?
- 10 Dalian Good University Ranking
- How about Foshan Shunde Hengan Property Management Co., Ltd.?
- How about supporting facilities around Fuyuan Community in Jacky?
- Which is the higher quality, Zhong Jian or Greentown?
- Is Yantai Tianjing Kunyu Zhonghua Courtyard Villa decorated?
- Which school district does Zhuji Yaojiang Sunshine Garden belong to?
- Is the Linglanyuan House in Peacock City in Gu 'an a 70-year property right?