1, after the completion of the building (structure) general plan, building fire control facilities layout, building fire control facilities system diagram, safety exit layout, key position map, etc. ; ? 2, fire safety management rules and regulations, emergency fire fighting plan, emergency evacuation plan, etc. ; ? 3, fire safety organization chart, including fire safety responsible person, management personnel, full-time, voluntary firefighters, etc. ; ? 4、? Records of fire safety training, fire fighting and emergency evacuation plan drills; 5, on duty, fire safety inspection and inspection records; 6 list of fire control facilities, including the type, quantity and condition of fire control facilities; ? 7. Description of the logical relationship between fire protection system, equipment operation instructions, system operation procedures, system and equipment maintenance system. ? 8、? Equipment operation status, alarm record, fire treatment, equipment maintenance inspection report and other information should be kept and filed regularly.
? Management requirements and classification details of fire control room
The overall scheme of equipment configuration, monitoring requirements, account files and management norms in the fire control room;
The fire control room is equipped with automatic fire alarm system control equipment and fire linkage control equipment, which are used to receive, display and process fire alarm signals and control related fire control facilities. It is the information and command center for directing fire fighting and guiding personnel to evacuate safely, and the core place for fire safety management.
Video: Management and Operation of Fire Control Room
First, the fire control room equipment configuration
The fire control room shall at least be equipped with fire alarm controller, fire linkage controller, graphic display device of fire control room, fire telephone switchboard, fire emergency broadcast control device, fire emergency lighting and evacuation indication system control device, fire power supply monitor and other equipment, or equipped with combined equipment with corresponding functions.
Second, the monitoring requirements of fire fighting equipment
Fire fighting equipment equipped in the fire control room shall have the following monitoring functions:
1) The fire-fighting equipment set in the fire control room can monitor and display the operation status information of fire-fighting facilities, and can transmit the corresponding information to the urban fire remote monitoring center (hereinafter referred to as the "monitoring center").
2) According to the scale of the building (unit) and its fire risk characteristics, the fire control room needs to keep necessary written and electronic materials.
Store relevant fire safety management information, and timely transmit the fire safety management information to the monitoring center.
3) Large buildings should be equipped with two or more fire control rooms according to their different building functional requirements, fire hazard characteristics and fire safety monitoring needs, and the main fire control room and sub-fire control room should be determined to realize the fire safety monitoring mode combining decentralization and centralization.
4) The fire-fighting equipment in the main fire control room can control the fire-fighting equipment used in the system and display its status information, as well as the status information of the fire-fighting equipment in each fire control room, which has the control function of the fire-fighting equipment in each fire control room and the fire-fighting system and equipment controlled by it.
5) The fire-fighting equipment in each fire control room can transmit and display status information to each other, but cannot control the fire-fighting equipment to each other.
Third, the establishment of fire control room ledger files
Keep at least the following paper ledger documents and electronic materials:
1) after the completion of the building (structure), the layout and system diagram of construction site plan and fire fighting facilities, the layout diagram of safety exits, the location diagram of key parts, etc.
2) Fire safety management rules and regulations, emergency fire fighting plan, emergency evacuation plan, etc.
3) Fire safety organization chart, including fire safety responsible person, management personnel, full-time and voluntary firefighters, etc.
4) Records of fire safety training, fire fighting and emergency evacuation plan drills.
5) Duty records, fire safety inspection and patrol records.
6) List of fire control facilities, including the type, quantity and status of fire control facilities.
7) Description of control logic relationship, equipment operating instructions, system operating rules, system and equipment maintenance system and technical regulations of fire fighting linkage system.
8) Information such as equipment operation status, alarm records, fire treatment, equipment maintenance test report, etc.
The above ledgers and materials shall be filed and kept regularly according to the requirements of filing management.
Requirements for file creation and management:
1. file content
The archives of building fire control facilities shall at least include the following contents:
(1) Basic information of fire control facilities. It mainly includes the original technical data such as the acceptance opinions of fire-fighting facilities, products, system operating instructions, system debugging records, fire-fighting facilities layout, system drawings, etc.
(2) Dynamic management of fire control facilities. It mainly includes the duty records, patrol records, inspection records, fault maintenance records, maintenance schedule, maintenance records, basic information files, training records, etc.
2. Preservation period
Long-term preservation of original technical data such as building installation, completion acceptance and acceptance technical inspection of fire control facilities; "Fire Control Room Duty Record Form" and "Building Fire Control Facilities Inspection Record Form" shall be kept for not less than one year; Inspection records, fault maintenance records, maintenance schedules and maintenance records of building fire control facilities shall be kept for at least five years.
Four, fire control room management requirements
(1) Responsibilities of fire control room
1) A 24-hour duty system shall be implemented, with no less than two people in each shift, and the personnel on duty shall hold the specified fire-fighting professional skill appraisal certificate.
2) The daily maintenance and management of fire fighting facilities conforms to the national standard Maintenance and Management of Building Fire Fighting Facilities (GB2520 1-20 10).
3) Ensure that linkage control equipment such as automatic fire alarm system and fixed fire extinguishing system are in normal working condition, and equipment that should be in automatic control state should not be set to manual control state.
4) Ensure that there is enough water in fire water storage facilities such as high-level fire water tank, fire water pool and pressure water tank, and ensure that the valve on the outlet pipe of fire pump and the pipeline of automatic sprinkler system are always open; Ensure that the control device of the power distribution cabinet of fire-fighting electrical equipment such as fire pump, smoke exhaust fan and fire shutter is in the automatic control position (or energized state).
(2) Emergency handling procedures for fire control room
In case of fire, the personnel on duty in the fire control room shall handle the fire according to the following emergency procedures:
1) After receiving the fire alarm, the personnel on duty shall immediately confirm the fire in the fastest way.
2) After confirming the fire, the personnel on duty immediately confirm that the fire alarm linkage control switch is in the automatic control state, and dial "1 19" to give an accurate alarm; When giving an alarm, the location of the fire unit, fire location, fire type, fire size, name and contact number of the alarm person shall be indicated.
3) The personnel on duty shall immediately start the emergency evacuation and initial fire fighting plan of the unit and report to the person in charge of fire safety of the unit.
(3) Control and display requirements of fire control room
1. Graphic display device for fire control room
The diagonal length of graphic display device in fire control room with Chinese label and Chinese interface should not be less than 430 mm The graphic display device in the fire control room displays relevant information according to the following requirements:
1) can display the above-mentioned electronic data and fire safety management information that meet the requirements.
2) The same interface can display the fire truck passage around the building (structure), the operation site of fire-fighting climbing vehicle, the location of fire-fighting water source, the fire-fighting distance, building area, building height and use nature of adjacent buildings.
3) It can display the names and locations of fire-fighting systems and equipment, and the dynamic information of fire-fighting controllers and fire-fighting linkage control equipment (including fire-fighting telephones, fire-fighting emergency broadcasts, fire-fighting emergency lighting and evacuation indication systems, fire-fighting power supply and other control devices).
4) When inputting fire alarm signal, monitoring alarm signal, feedback signal, shielding signal and fault signal, special general instructions with corresponding states shall be provided. The location of the building (structure) where the input signal is located should be displayed in the general plan, and the location and name of the input signal should be displayed in the building plan, and information such as time, signal type and location should be recorded.
5) The status information of the input fire alarm signal and feedback signal can be displayed within 5) 10s, and the status information of other input signals can be displayed within 100s.
6) It can display the alarm information, fault information and related linkage feedback information of combustible gas detection and alarm system and electric fire monitoring system.
2. Fire alarm controller
The fire alarm controller can display the normal working state, fire alarm state, shielding state and fault state of the fire detector, fire display panel and manual fire alarm button, and can control the start and stop of acousto-optic fire alarm.
3. Fire linkage control equipment
The fire-fighting linkage control equipment can transmit the state information of various fire-fighting facilities and their equipment to the graphic display device; It can control and display the power supply working state of various fire-fighting facilities, the running state and fault state of various equipment and its components, display the normal working state and action state of valves and monitoring devices with control function and signal feedback function, control the start/stop of fire-fighting equipment with automatic control and remote control function, and receive their feedback signals.
- Related articles
- What types of funds are there besides ETF funds?
- How about Shanghai Shen Da Property Management Co., Ltd.?
- What about the surrounding facilities of Yinchuan Happy Island Community?
- What good-looking and literary time-travel novels are there? ....
- How to deal with the noise in housing construction
- Why is the price of Huishui Heyuan low?
- What is the telephone number of Guangyuan Sunshine Yuncheng Marketing Center?
- What is the local real estate level in Yantai?
- Which subway can Urumqi take to Daguan Community in North City?
- What about the surrounding facilities of Liuxi Beauty Salon in Taigu, Linyi?