Answer: The first gas station is a retail unit, and its petrochemical sales system faces the society and directly serves users.
The affairs are extensive and political. In order to improve the management level of gas stations and better serve the socialist construction,
In order to do a good job in the retail supply of petroleum commodities, this system is formulated.
Article 2 Petroleum commodities are flammable, explosive, volatile, easy to leak and easy to accumulate electrostatic charges. increase
Gas stations must establish the idea of "safety first" and implement the policy of "prevention first, combining prevention with elimination" to ensure that
Safe operation.
Article 3 Gas stations shall establish the concept of "customer first", formulate service standards and popularize polite expressions.
Improve service quality and keep the station clean and tidy.
Article 4 A gas station must establish a post responsibility system and safety operation rules from stationmaster to each type of work.
It is necessary to achieve a specific division of labor, clarify responsibilities, and formulate assessment methods and reward and punishment methods to ensure the implementation of this system.
Article 5 gas station staff must be trained to learn about petroleum commodities and oil engines.
Master the essentials of business operation, be familiar with the management system of gas stations, and pass the examination by the competent department at or above the regional branch.
Only after passing the nuclear test is it allowed to operate in his post.
Article 6 Gas station staff shall keep their appearance clean and tidy, wear service badges and be polite and civilized.
In operation, strictly implement the supply policy, price policy and relevant management regulations, and prohibit the sale of adulterated and deteriorated water.
Petroleum products.
Article 7 Gas stations must strengthen economic accounting, improve management, reduce commodity consumption and flow.
Transfer costs and improve economic benefits.
Eighth gas stations must strictly implement the ticket and cash management system, complete procedures and explain clearly.
The records are clear and the accounts are consistent.
Ninth new construction, expansion and reconstruction of gas stations, must meet the requirements of design and building codes, after
Completion acceptance, complete equipment, qualified quality, complete information can be put into production. After production, all kinds of equipment
Establish a complete technical file and maintenance management system.
Tenth gas stations should be in the obvious position of the gas station hanging signs issued by China Petrochemical Sales Company.
In order to strengthen the construction of workers' spiritual civilization, improve the quality of work, safeguard the reputation of the industry and enhance the unity of the industry (symbol
The diameter is 100- 150 cm). Signs should be made in strict accordance with the requirements of design drawings and hung safely and reliably.
Always keep clean and complete, and maintain the seriousness of corporate identity.
Article 11 A gas station shall adopt a closed unloading method.
Article 12 In order to ensure the safe operation of gas stations, a sound safety organization must be established.
(a) each shift must designate a person responsible for fire safety.
(two) to have a part-time on-site safety inspector, responsible for the supervision and inspection of the safety management measures at the refueling site.
(3) Establish mass fire control organizations, conduct regular safety education and strengthen fire control technical training.
Do the combination of prevention and elimination.
Thirteenth to formulate and implement enterprise safety measures.
(a) to develop the "user refueling instructions", mainly including:
① Fireworks are strictly prohibited in the station.
(2) It is forbidden to engage in operations that may generate sparks at the gas station, such as not allowing vehicles to be overhauled in the station.
Don't knock the iron, etc.
(3) It is forbidden to fill gasoline into the carburetor and plastic bucket of the car.
(4) All motor vehicles must be turned off and refueled. Motorcycles, Qingqi, tractors, etc. are unnecessary. Stop before entering the station.
Must be started in the station.
⑤ It is forbidden to bring all dangerous goods into the station.
(two) it is forbidden to enter the gas station and stay in the gas station.
(3) When high-intensity lightning strikes, lightning strikes and frequent lightning strikes occur, stop refueling.
Fourteenth to strengthen the management of open flame.
(1) The use of fire shall not be changed or expanded except for the fixed fire points approved by the superior competent department.
Surround and fire at will.
(two) due to equipment maintenance and other reasons. If it is really necessary to use an open flame, it shall be reported to the higher authorities in writing for approval.
After that, stop refueling operation and take reliable safety measures before hot work can be carried out.
(three) no open flame shall be used for heating in the gas station.
Fifteenth gas station and other units around the building fire safety distance, gas station internal buildings.
The fire safety distance and fire safety distance between the open flame operation point and other buildings shall comply with the design specifications.
Rules.
Article 16 When the oil pipeline from oil tank to tanker is laid in pipe trench, it should be covered with sand around the pipeline.
Fill with soil.
Article 17 Provisions on Safe Use of Electricity
(a) the bottom of the tank car is 0.5 meters upward, 4 meters horizontally, and the tank mouth is within 3 meters horizontally.
Dangerous area.
The selection, installation and use of electrical equipment in hazardous areas must comply with relevant electrical safety regulations.
(2) It is forbidden for overhead lines of any voltage level to cross the gas station.
(3) Outdoor lighting lamps and lanterns must be closed.
(four) temporary wires shall not be connected at will in the gas station.
Article 18 Anti-static regulations
(1) There should be no two groups of electrostatic grounding devices at the head and tail ends of the underground horizontal oil tank, and the resistance value should not be large.
10 ohm. The connecting flat iron or wire between the tank body and the grounding electrode shall be connected by bolts and asphalt.
Anticorrosion treatment. The resistance value of electrostatic grounding devices in other parts shall not be greater than 100 ohm. Electrostatic grounding device
It should be tested twice a year.
(2) The oil inlet pipe of the underground horizontal oil tank should extend downward to a distance of 15cm from the bottom of the tank and have an elbow. No splashing water
Type of oil supply.
(3) The static elimination connecting line and refueling hose on the tanker must be in good condition and effective.
(four) gas station staff shall not wear chemical fiber clothing.
Article 19 fire fighting
(a) the station shall formulate a fire fighting plan according to the relevant regulations and the actual situation of the station, and prepare a chart to show it.
Ming, as the main basis for actual combat and fire fighting training. The contents include:
(1) Organizational leadership and command system.
(2) the geographical location of gas stations, the number and volume of oil tanks, the location and pipeline direction of tankers, and other oil products.
Storage location and quantity of.
(three) the allocation and division of fire fighting personnel, the allocation and arrangement of security forces, and the rescue measures for materials.
④ Structural form, fire resistance rating, area, height, interior and spacing of buildings in the station.
(5) the ministries and quantity of fire-fighting equipment, the location and name of existing fire-fighting equipment,
Quantity.
⑥ Operating procedures, time requirements and emergency supplementary measures for fire fighting and relief materials.
⑦ External communication, deployment and command of external support forces, etc.
(2) Configuration of fire fighting equipment:
① Gas stations with two tankers should be equipped with 3kg CO2 fire extinguishers or "12 1 1" fire extinguishers.
4; 2 8 kg dry powder fire extinguishers or 65 kg dry powder fire extinguishers; Four asbestos quilts; 0.5 cubic meter sand box
2; Four fire shovels. Set up more than two gas stations equipped with tankers, and increase the allocation of fire-fighting equipment in proportion.
(2) The distribution of fire-fighting equipment should be mainly oil tanks and refueling areas, which should be neatly arranged, with reasonable locations and smooth roads.
Easy to carry and use.
(3) Fire fighting equipment shall be managed by special personnel, inspected on time, maintained and replaced regularly to ensure good condition.
Effective.
Article 20 Safety inspection
(1) The stationmaster of the gas station should conduct a comprehensive inspection of the gas station every month in addition to strengthening the daily routine inspection.
It is really difficult to check, formulate rectification measures for the problems found out, and solve them quickly if they can solve them themselves.
It is necessary to truthfully report to the superior in writing. If the delay causes losses, the responsibilities of relevant departments and personnel shall be investigated.
(2) The on-site safety inspector shall urge the employees on this site to seriously abide by the safety operation procedures and post responsibility system.
Have the right to stop and reflect illegal operations.
(three) the competent department of gas stations should regularly check the safety work of gas stations every quarter and major festivals.
The main contents of the inspection include: the importance of employees to safety work, the progress of rectification of identified hidden dangers,
The implementation of various rules and regulations, the activities and functions of safety organizations, the technical conditions of various equipment, etc. correct
The problems found should be sorted and queued, the responsibilities should be implemented, and rectification should be made within a time limit.
Twenty-first gas stations must report accidents to the competent authorities in a timely and truthful manner in accordance with regulations.
Situation. Explosion, fire, lightning strike, casualties, serious injuries and other property losses 1 ten thousand yuan or more.
Major accidents should be reported to petrochemical sales companies through companies in provinces, municipalities and autonomous regions. For accidents, to
In line with the principle of "three-no pass", we will deal with it seriously.
Article 22 Preparation before opening
(1) Handover contents include: cumulative refueling times, fuel tank volume, tickets and other related matters.
Appropriate, clear handover, both parties sign the record for approval.
(two) the succession of refueling personnel to check the technical condition of refueling equipment.
(3) According to the density of oil at the standard temperature provided by the metering personnel, the volume of oil paid is converted and adjusted.
Article 23 Refueling operation
(a) After the user's vehicle enters the station, the oiler should arrive at the vehicle and take the initiative to guide the vehicle to add in order.
Oil position.
(two) adhere to the provisions of refueling by ticket. Before starting the tanker, ask about the empty capacity of the fuel tank and put the tanker on for the last time.
The digital code of refueling quantity is zero, and the refueling quantity must be consistent with the number of recovered fuel tickets.
(3) The oiler must personally control the oil gun. Do not twist the fuel hose or stretch it to the limit. Compressor spray gun
Insert firmly into the fuel filler of the fuel tank, concentrate and operate carefully to avoid overflow or risk.
(four) when the tanker accident and endanger the safety of the gas station, should immediately stop refueling.
In case of oil leakage, spill and spill, the refueling truck must clean up the site before leaving.
Article 24 The reception of users and businesses shall not be affected by the settlement and counting of votes.
Twenty-fifth gas stations stop business, shut down the tanker, cut off the power supply, and close the oil tanks in and out.
Pipe gate valve, lock the doors and windows.
Article 26 Receiving and unloading of bulk oil products
(a) the gas station according to the inventory and business dynamics, put forward the varieties of purchase application plan, timely approval.
Weave the source of goods to prevent people from out of stock.
(two) after the tanker stops, it should be guided to stop at the designated location, turn off the engine and stop refueling at the same time.
For operations (except closed oil unloading and isolation of tank farm and refueling area), do a good job in safety alert and arrange in time.
Pick up and unload.
(three) check the delivery documents, check the seals, check the name and quantity, determine the stock of oil tanks, and check.
Calculate the capacity and make records.
(4) When receiving and unloading oil products, strictly abide by the operation procedures, and connect the electrostatic grounding device before unloading oil. location
There is a special person to supervise and prevent accidents such as leakage, leakage and oil mixing.
(5) After oil unloading, you must get on the bus for inspection and collect the remaining oil at the bottom. After the oil is stable for five minutes, retest the oil tank.
Purchase goods, check out the quantity, go through the signing formalities and register.
Twenty-seventh packaging oil (including large and small packaging of lubricating oil and grease), to count the number of pieces, re inspection.
After measuring and checking the shipping marks, go through the signing formalities and register.
Article 28 Storage of bulk oil products
(a) bulk oil must be divided into tanks to establish a commodity storage account, timely record the receipt, delivery and storage dynamics, to ensure that
The accounts and goods are in conformity and overflow.
(2) Measure the water level of the oil tank once a month, and eliminate the accumulated water in the tank in time.
(three) according to the types and specifications of oil products, the use of special storage tanks. When the oil tank is changed to store other oil products, the oil tank should be cleaned.
Save fuel.
Article 29 Storage of packaged oil products
(1) All lubricating oils and greases must be put into storage, stacked in categories, clearly marked and built according to varieties.
Establish a storage card, make regular inventory, and ensure that the accounts and goods match.
(two) the establishment of barrel (listening) leak detection system, found that the leakage should be handled in a timely manner.
(3) Brake oil, antifreeze and other oil products must be tightly packed and not stored in the open air.
Thirtieth all kinds of oil products must be rotated according to the principle of first in first out, and ensure that the oil products are out of the warehouse.
Quality.
Thirty-first gas stations must be equipped with qualified part-time metering personnel.
Article 32 The basic tasks of metrological personnel are:
According to the metering operation regulations, metering must be carried out before and after each oil collection operation and after daily shutdown.
Make a complete record and provide the change of oil storage capacity in the fuel tank in time.
Article 33 Newly-built oil tanks and various measuring instruments can only be used after verification. all
Volume tables shall be prepared for all oil tanks.
Article 34 The verification cycle of oil tanks is: new tanks are re-examined every three years, and then every five years. Yinmou
The fuel tank that is obviously deformed due to this reason must be re-verified before it can be put into use.
Article 35 stipulates the verification period of the following measuring instruments: the tanker and dipstick are verified once every six months;
Thermometers and densimeters should be calibrated once a year; The standard table shall be submitted for inspection according to the period stipulated by the state.
Thirty-sixth gas stations should be gradually equipped with a standard meter, and check the accuracy of the tanker once a month.
If it exceeds the tolerance, it should stop running and report to relevant departments for maintenance. Units and individuals that pick up the car without approval shall not be dismantled.
Lead seal of measuring device.
Article 37 In accordance with the requirements of the Measures for the Administration of Natural Loss of Petroleum Products, transportation, unloading,
Establish a unified list of operating losses such as warehousing and retail, designate special personnel to be responsible for management, and actively take measures.
Minimize losses.
Thirty-eighth losses must be dealt with realistically, and shall not be falsified or passed on to users.
Thirty-ninth bulk storage of oil must be calculated daily profit and loss, monthly verification. Seek repeated profit and loss
Yes, we should find out the reason in time and solve it. Retail losses should be written off once a month. Transport overflow, consignee
Bear the quota loss, the shipper bears the overflow, and the responsible party bears the excess consumption.
Article 40 Oil tanks
(1) The oil tank shall be installed horizontally with an inclination of no more than 8%.
(2) The anti-corrosion protective layer of the fuel tank is intact. After three years of production, it should be noted that the oil tank is directly buried underground.
Check the anticorrosive coating.
(3) The oil tank has no serious deformation or leakage. .
(4) Cleaning cycle of oil tank: the light oil tank shall not exceed three years, and the corrosion process of oil tank shall be checked in combination with cleaning.
Degree. The remaining thickness of 4 mm tank wall is less than 2.5 mm, so it should be stopped.
(5) Each oil tank shall be clearly marked with oil products to prevent oil mixing.
Article 41 Oil tank accessories
(1) The bolts connecting manhole and oil tank are complete and tightened.
(2) The oil inlet and outlet pipes, oil measuring ports and oil inlet holes are firmly connected, and oil-tight parts are complete.
(3) The valve shall be flexible in opening and closing, tightly closed and without leakage.
(4) The flame arrester is in good condition and effective. The diameter of the vent pipe is not less than 50 mm; Not less than 4 meters above the ground, and
On the top of the gas station building. The open end of the vent pipe shall be equipped with a metal or corrosion-resistant perforated mesh cover.
Mesh is not less than 6mm.
Article 42 the pipeline
(a) pipeline strength test once every one to two years.
(two) directly buried pipelines, after five years of production, should be excavated and inspected every year, and the anti-corrosion layer is found to fall off.
Efficiency and leakage, timely maintenance.
Article 43 Oil tankers and accessories
(a) the measurement error of the tanker shall not be greater than 0.3%.
(2) Do not check the tanker with water to prevent the parts from rusting.
(3) Do a good job of keeping the tanker warm in cold season to prevent the water in the tanker from freezing.
(four) the mechanical wear parts of the tank car should be lubricated frequently.
(five) the tank car should be regularly overhauled to check the technical conditions of various components and parts. Maintenance cycle: large
Maintenance for 3 years; Secondary school 1.5 years; Minor repair for 0.5 years.
Forty-fourth refueling hose should be able to withstand the test pressure of 5 kg, with enough elasticity, users.
Shit.
Article 45 the refueling gun should be flexible switch, good seal.
Forty-sixth car chassis elevator should be flexible, the body is in good condition, regularly check the oil mark, found that
Insufficient hydraulic oil and impure oil should be replenished and replaced in time.
Article 47 The working pressure of the air compressor shall not exceed the value specified on the nameplate, and the storage capacity shall be released every day.
Check the safety valve at least once a week, clean the filter once a month, and change the oil in the air reservoir once a quarter.
Compression testing must be done once a year.
Article 48 The illumination of the upper part of the tank car shall generally not be lower than 100 lux.
Article 49 car wash service. Never discharge car wash pollution at will to prevent environmental pollution.
Fiftieth to carry out lubrication services. The fuel injection quantity reaches the lubrication standard, and the oil used is reasonable, economical and safe.
Keep the site clean.
Fifty-first to carry out battery electrical quality testing services. Charging should reach the specified voltage.
Fifty-second to carry out the standard measurement service of automobile exhaust emission.
Chapter VIII Supplementary Provisions
Article 53 Oil companies in provinces, municipalities and autonomous regions may, in accordance with the provisions of this system and in light of the actual conditions in their respective regions.
Actually formulate supplementary provisions and report them to China Petrochemical Sales Company for the record. .
Fifty-fourth oil companies in all provinces, municipalities and autonomous regions should increase or decrease gas stations in the following year.
1 Report to China Petrochemical Sales Company before the end of the month.
Article 55 This system shall be implemented as of the date of promulgation. The right to interpret and modify this system belongs to China Stone.
Chemical sales company. : Zhong Xu Business School.
Shandong Institute of Chemical Technology covers an area?
Shandong Vocational College of Chemical Technology covers an area of 550 mu, with a building area of 1.28 million square meters.
Shandong Vocational College of Chemical Technology is a public full-time college approved by the Shandong Provincial People's Government and put on record by the Ministry of Education. It was founded by Qilu Petrochemical Company of China Petrochemical Group and continued by Weifang Municipal People's Government.
The college has 9 teaching units and 20 higher vocational majors. There are more than 300 full-time (part-time) teachers and more than 7,400 students.
On 20 17, the college became a public full-time general college continued by Weifang Municipal People's Government.
Does Shandong Vocational College of Chemical Technology have a campus card?
When the admission notice of Shandong Vocational College of Chemical Technology was issued, there was also a campus card of Unicom, so Shandong Vocational College of Chemical Technology had a campus card.
Shandong Vocational College of Chemical Technology is a public full-time college approved by the Shandong Provincial People's Government and put on record by the Ministry of Education. It was founded by Qilu Petrochemical Company of China Petrochemical Group and continued by Weifang Municipal People's Government.
In 2003, Qilu Petrochemical Company of China Petrochemical Group established Shandong Chemical Vocational College; On 20 17, the college became a public full-time general college continued by Weifang Municipal People's Government.
Weifang Chemical Vocational College District?
Shandong Vocational College of Chemical Technology covers an area of 550 mu, with a building area of 1.28 million square meters.
Shandong Vocational College of Chemical Technology is a public full-time college approved by the Shandong Provincial People's Government and put on record by the Ministry of Education. It was founded by Qilu Petrochemical Company of China Petrochemical Group and continued by Weifang Municipal People's Government.
The college has 9 teaching units and 20 higher vocational majors. There are more than 300 full-time (part-time) teachers and more than 7,400 students.
On 20 17, the college became a public full-time general college continued by Weifang Municipal People's Government.
What are the application conditions for the safety production license of hazardous chemicals?
Application conditions for hazardous chemicals business license:
I. Site requirements
The business address needs to be more than 40 square meters, with office nature, building fire protection and secondary fire protection, and there can be no restaurants nearby. A hotel over 300 square meters needs secondary fire protection, but it doesn't need secondary fire protection under 300 square meters, but the property needs to provide proof that there is no secondary decoration.
Second, the personnel requirements
The main person in charge and safety management personnel of the enterprise have the knowledge and management ability of safety production suitable for the business activities of dangerous chemicals in the enterprise, have passed the examination of special safety production training, hold the examination certificate of Shenzhen Safety Supervision Bureau, pay social security for three months in the company, and appropriately increase the safety management personnel according to the number of projects in the company.
Third, safety labels.
Each business scope should have MSDS and safety labels for chemical safety technical specifications. There is no warehousing, and appropriate warehousing and transportation agreements are needed.
Fourth, the emergency plan
There is an emergency plan for hazardous chemical accidents in line with state regulations, and necessary emergency rescue equipment and equipment are provided.
At present, there are many requirements for operating licenses for hazardous chemicals in Shenzhen, and the government's jurisdiction is very strict! It's difficult to deal with it now, so we must find a professional, Tengbo International.
- Previous article:How many kilometers is it from Taiping Red Agate Square to Kyoto, Fuxin County?
- Next article:Yifeng recruitment network
- Related articles
- Recruitment in Mu Sha
- What about Guang 'an Longhui Construction Engineering Co., Ltd.?
- Who are the celebrities in Ganyu County?
- Is the preparation of teacher files in Duanzhou District, Zhaoqing City at the Human Resources and Social Security Bureau?
- How far is Guangzhou Dagang Tanzhou Middle School from Lida Shoes Factory?
- What is the significance of uv in printing?
- What's the treatment of tianma microelectronics Company?
- What is the employment prospect of petrochemical industry?
- What are the delays in Shuangfeng County?
- What about Huaying Jinyang Guang Agricultural Technology Co., Ltd.?