Parameter adjustment of bottle blowing machine

This is the result of the parameter setting problem:

1, temperature not reached.

2. The air pressure is too low

This needs professional debugging. Generally, Tengyue bottle blowing machine will make adjustments for customers in the after-sales process. You can ask the master of Tengyue bottle blowing machine for help.

3. The setting parameters of different bottle sizes are different. The drawing parameters are generally 0.6 ~ 1.5, and the pre-blowing time is generally 0.2 ~ 0.5. As long as the customer's requirements are met, the shorter the blowing time, the better.

Extended data:

Matters needing attention in bottle blowing machine maintenance:

1 bottle cannot be ejected after blowing.

First, you have to open the mold and open and close it manually. If it is normal, it runs in the idle running state, if it is normal.

Please check your exhaust time setting. If the exhaust setting is normal and every bottle blowing fails, then it can be judged that it is a problem with the exhaust valve. Please open the exhaust valve and check its spring and sealing condition (another phenomenon of this fault is loud exhaust sound or unclean sound).

If many molds are produced normally and can't be opened occasionally, please check whether there is broken wire in the lock pin, and also check whether the locking force is too large. If it is too large, it should be readjusted according to the standard.

The bottle is always pinched.

Whether the position of the manipulator is misplaced.

3 Two manipulators collided.

This situation requires manual reset of the manipulator, which is caused by dislocation.

4 There is no feed at the feed position: several conditions need to be checked:

Is there no material in the hopper? If it is, it needs to be fed quickly.

No: Please check whether the control contactor of the hoist is energized. If so, check whether the motor is energized and loaded as soon as possible, because the bottle blank (embryo) is likely to get stuck in the lifting belt, and the easiest way is to help the crane manually.

If the control contactor of the hoist is not energized, please check whether the electric eye for bottle embryo detection is not in a straight line with the reflector.

5 feed the old card to feed the tray: this situation is very headache. From the experience, if the length of bottle blank (embryo) is relatively long and the cutting weight is relatively large, then this phenomenon is relatively rare.