Wuxi Aux Air Conditioning Maintenance Telephone
First, the refrigerant is insufficient. We need to check whether the refrigerant is insufficient, and then add the refrigerant appropriately. Then restart the test to see if the fault is solved.
Second, it may be the radiator of the air conditioner. The filter screen has not been cleaned for a long time, and there is a lot of dust and foreign matter on the surface, which leads to insufficient heat dissipation and low heat dissipation efficiency, triggering undervoltage protection. At this time, the filter screen should be removed and cleaned, and the radiator should also be cleaned, then dried and put back to start the test again.
Third, if all the above are all right, then you need to check the reasons from the inside of the air conditioner. We need to confirm whether it is an internal machine or an external machine first. The specific operation is as follows: disassemble the air conditioner shell, short-circuit the LPP plug on the main control board and the zero line on the main board, and observe whether the indoor unit operates normally. If it is normal, it means that the outdoor unit has a high failure probability and needs to be checked. Mainly check the connecting wires, plugs and low-voltage switches of indoor and outdoor machines. Use multimeter to short-circuit LPP to protect the first line and the zero line of outdoor unit. If the resistance value is zero, the fault is in the low-voltage switch. It is generally difficult to repair the fault of low-voltage switch, which is time-consuming and laborious. It is recommended to change it directly to a new one, and it won't cost much. If the resistance is normal. It means there is something wrong with the circuit. It is necessary to short-circuit all electronic components on the circuit board with a multimeter, and judge whether electronic components are damaged, especially capacitors, according to the change of their resistance values. If electronic components are damaged, it is recommended to replace the circuit board directly, because the replacement of electronic components is also more troublesome.
Through the above investigation, we can generally find the cause of the fault, the external fault is relatively easy to solve, and the investigation of the internal circuit and motherboard of the air conditioner is more complicated. It is recommended to find specialized maintenance personnel to solve it.
- Related articles
- How about Hairong Cold Chain Company?
- How is the treatment at Tengzhou Wangchao Coal Mine?
- Announcement on open recruitment of teachers and staff of East China University of Political Science and Law
- Jiangyin Tongli photoelectric tired not tired?
- Does Shijiazhuang subway recruit people every year?
- Shenyang Xinhongxuan Food Wholesale Station recruitment information, how about Shenyang Xinhongxuan Food Wholesale Station?
- Where can I teach Go online?
- Light: several fields of advanced manufacturing industry
- May I have the contact information of the human resources department of Shengli Oilfield?
- Did the interview in Aoyama, Indonesia go well?