Job Recruitment Website - Job information - True or false: adjusting antenna height and pitch angle, increasing base station transmission power and other methods can be used to solve ch congestion. ? ( )

True or false: adjusting antenna height and pitch angle, increasing base station transmission power and other methods can be used to solve ch congestion. ? ( )

RX=-87.73 TX=-4 1.08。 The gap is too big. Check the standing wave ratio of RX feeder (including two 1/2 feeders and antennas) with a standing wave ratio tester. It may be due to poor contact of the feed head or water ingress. Please ask the tower worker to go up to the tower to check whether there is any tape or cement opening.