1, the selection of civil air defense engineering equipment should conform to the national fixed standards. It is strictly forbidden to build self-made products by construction units. The construction unit is responsible for procurement and installation. The embedded parts of the equipment must be embedded in place. Measures that cannot be installed in place at ordinary times must be put in place and piled up in a centralized way. 2, it is strictly prohibited to change without authorization and not according to the figure construction, really need to change to the civil air defense department for examination and approval, even if the reasonable suggestions to review. 3, must be carried out in accordance with the relevant requirements of the region, such as must be accepted by the civil air defense office before entering the next working procedure, supervision team to urge the construction unit to abide by the acceptance procedures, regardless of whether it must be accepted by the civil air defense office, the process should be accepted by the supervision on the basis of the self-inspection of the construction unit, and the supervision should also conduct parallel inspection in the process. The construction unit should do a good job of self-inspection. After the acceptance of the supervision team, the construction unit shall report it to the quality supervision station and the civil air defense office for acceptance. 4. Process acceptance: (1) Cushion and brick tire mold are actually templates, and the smoothness of cushion basically meets the requirements. Cushion thickness must meet the design requirements. Waterproof should be constructed continuously, and it should be put in place as soon as possible. If continuous construction is not possible, the lap length should not be less than 20cm. (2) Floor reinforcement: First of all, consider that the specifications and connection methods must meet the requirements. The mesh of upper and lower steel bars should be visually observed in the same direction on the same longitudinal axis plane, and the hook should be in a vertical state and put in place. Double mesh, the upper mesh should pass under the ground beam, and the effective height of the mesh is too small. All parts in contact with the ground beam must be tied together with tie wires. The first process should be strictly controlled, and each process is the beginning of the next process. The tractor must be placed in a quincunx shape, starting from the first row of the ground beam. If the spacing is designed to be 50cm and the mesh is 20cm, only 40cm can be found, and the binding personnel of the tractor cannot walk on it. Wall panel: at the junction with the bottom plate, at the junction of the inner and outer walls, and under the steel plate waterstop (50cm), it must have been inserted into the outer wall by mistake, which refers to the horizontal reinforcement. Whether the material of steel plate water stop meets the design requirements, the welding with a thickness of 4mm shall not be less than 3.8mm, whether butt welding or lap welding, the lap welding shall not be less than 5cm, the inside and outside of unit height shall be fully welded, and the welding spot height shall be fully welded to control the welding quality. Welders should hold relevant certificates and observe the welding quality on site. After welding, the upper and lower positions and horizontal positions should be centered. When the main reinforcement of the abdominal column conflicts with the water stop, the main reinforcement of the abdominal column must be considered. At the exhaust position, there are two vertical bars on both sides of airtight closed passage, wall, door frame wall and door opening, with the wall thickness within 30cm, three vertical bars on the opposite door within 30cm~50cm, two diagonal bars at the corner and three vertical bars within 30cm ~ 50cm. The bottom reinforcement must be anchored in the bottom plate and the top diagonal reinforcement must be anchored in the top plate. The starting position of the threshold stirrup starts from the bottom 5cm, and the stirrup is a closed hoop. The elevation of the sill reinforcement relates to the installation of the protective sealing door, so it must be closed correctly. The horizontal reinforcement includes the openings of all horizontal stirrups of the explosion-proof door, and the openings facing away from the door. In the final analysis, vertical steel bars, especially external walls and airport walls, are not allowed to overlap. The vertical reinforcement of the wall should be basically vertical to the wall, and the anchorage on the outside of the outer wall should overlap with the roof horizontally. There should be no deviation in the height of the external wall reinforcement from the cushion to the roof, so as to avoid the vertical reinforcement of the external wall being too low and overlapping with the roof. The horizontal bar can't wriggle, the height should be horizontal and vertical, and all parties should pay attention to control.
- Related articles
- Shanghai hengpu trading co., ltd. recruitment information, how about Shanghai hengpu trading co., ltd.
- How about Hefei Lianbao Electronics Factory?
- Why did Chengdu Sichuan Industrial Park settle in Pixian County?
- What questions will qa ask in an inexperienced interview?
- How about Haibei children's clothing?
- What about the port authority?
- What date will Mingguang Jiuxingyuan¡¯s salary be paid?
- How is the appointment letter of Taihe County Natural Resources and Planning Bureau the following document of Fuyang Municipal Bureau?
- How about Yulin Borun Automobile Sales Co., Ltd.?
- What does a general worker do in Shi Min, Jiaxing?