Job Recruitment Website - Property management - Is there a relationship between heating and heating pressurization station?
Is there a relationship between heating and heating pressurization station?
1. There is gas in the radiator, which shows that a group of radiators is hot or not, for the bathroom radiator, it is hot at the bottom and not hot at the top, or there is water running sound in the radiator. Especially in the first half of heating, this often happens because there are many gases in the heating system of the whole community.
Solution: Always open the manual exhaust valve on the radiator until there are no bubbles in the running water.
2. The valve of the water separator is not opened.
Performance: Some radiators are hot and some are not.
Solution: Check whether each branch valve on the water separator is open. If not, tighten the valve handle parallel to the branch pipe.
3. The temperature control valve on the radiator is not opened.
The performance is that the radiator is not hot.
Solution: Check whether the inlet and outlet water temperature control valve of unheated radiator is open.
4. The radiator is not installed correctly.
The performance is: the radiator is partially hot, or only the lower supervisor is hot. If four radiators (also called upper inlet and lower outlet) are installed as lower inlet and lower outlet, water will flow out directly from the lower main pipe, only the lower main pipe is hot, the upper radiator is not hot, the lower inlet and lower outlet radiators are installed as upper inlet and lower outlet, and some radiators will not be hot, and so on.
Solution: Find the HVAC company that installed the radiator to reinstall or replace the radiator.
5. Radiator enters return pipe.
The performance is that the lower part of the radiator is hotter than the upper part without the reverse connection of the main pipe, and the heating effect is worse than normal.
Solution: find the company that installed the radiator and adjust it.
6. The temperature control valve is blocked.
Performance: the blocked radiator is not hot. Because the stolen goods in the system blocked the inner cavity of the temperature control valve, water could not pass through.
Solution: Find a property or HVAC company to remove the temperature control valve and clean it or replace it with a new one.
7. The radiator or system is blocked by stolen goods.
The performance is as follows: the heating effect of all radiators at home is lower than that of the previous year or stage, or some radiators are not hot at all, especially those users who have not installed filters on the outdoor supervisor.
Solution: find a property to thoroughly wash the whole heating system at home.
- Previous article:How to write a new year gift application for buying a house
- Next article:Which property company is Forte North Bridge City Phase II?
- Related articles
- How about Mulianzhuang Hotel in Guangzhou Pazhou International Convention and Exhibition Center? Are there any interesting places?
- How about the surrounding facilities of Fuyuan Community in Fu 'an, Jiaxing?
- What is the floor area ratio of Weishan Villa in South Lishui?
- How much is Xi Anshangjing Academy per square meter?
- How much is Kunming Jintai international house price?
- What's the telephone number of Wenshan Taihe Shui Yi Sales Office?
- Can I get my ID card on Saturday in Tongxin Ridge, Futian District, Shenzhen?
- Top 500 Buildings in China ¡ª¡ª A Witness to the Architectural History of China
- How far is Guanghua Changan Building from Yinhe soho?
- Can residential areas and holidays be decorated, and how to complain about disturbing the people.