Job Recruitment Website - Property management - What if the heating is not hot? ! ! ! ! ! ! ! ! ! ! ! ! To what extent should deflation be controlled?

What if the heating is not hot? ! ! ! ! ! ! ! ! ! ! ! ! To what extent should deflation be controlled?

There are mainly the following solutions. Just deflate until it is completely deflated. 1. The user should first check whether the inlet valve of the pipeline is open;

2. Close all valves at home;

3. When the upper and lower valves are closed, the user gently turns on the air valve, and immediately stops turning on the air valve after hearing the sound of exhaust, so that the air can be discharged by itself. Because the gas in the radiator accumulates at the top of the radiator, it is easily released under the action of atmospheric pressure;

4, gently loosen the inlet valve, until there is a stable water flow, and then close the vent valve. This step must be patient, just unscrew it a little and hear the sound of water, otherwise the gas will not be easily discharged;

5. Repeat the fourth step for many times until all the gas is exhausted. Some users have a lot of gas in the radiator system pipeline, which needs repeated exhaust to ensure the stability of heating.

There are many reasons why the radiator is not hot, and the air blockage of the radiator is the most common one. If the radiator hasn't warmed up after the user deflates, it is suggested that you can contact a professional institution for on-site inspection and maintenance.

Extended data:

When the floor heating is installed, the installation should be safe and planned. The installation of floor heating is not without layout. On the contrary, the layout of floor heating installation needs to be careful. It is necessary to consider the layout of floor heating according to the use area and the thermal insulation effect of the room, design the reasonable direction and spacing of floor heating pipes, provide the most suitable heat dissipation for the room according to the radiation principle, and make accurate calculations.

In order to achieve the best effect with the least number of pipes. Therefore, the use of floor heating is not as dense as possible. If the distance between the plates of floor heating is too large, it will cause the indoor temperature to be too high and very hot, which will affect people's health.

At the same time, the installation of floor heating does not mean that air conditioning can no longer be installed, because floor heating can only achieve the effect of heating, and when cooling is needed in summer, our air conditioning is still needed to exert its strength. Therefore, air conditioning should be properly installed at home to avoid being caught off guard when it is hot.