Job Recruitment Website - Property management - What is the fault maintenance method of electric glass door?
What is the fault maintenance method of electric glass door?
Induction electric glass door machine has anti-pinch function. When encountering obstacles or colliding with the induction electric glass door, the induction electric glass door cannot be opened normally. When it reaches three times, the induction electric glass door will stop running and the door leaf will stop opening or closing. In this case, it can be restored by pushing the door leaf to the fully open state.
Second, the belt in the induction electric glass door is installed backwards, which leads to the induction electric glass door not being closed.
When people pass by, the induction electric glass door is closed, but when people go far away, the induction electric glass door is opened, and it will not be closed again after opening. In this case, everyone will think that it can't be closed and opened. This problem is because the technicians are unprofessional, which leads to the reverse installation of the power belt when the induction electric glass door is installed or maintained. The solution is: 1 Replace the upper and lower buckle connections of the seat belt.
Thirdly, the controller failure caused the induction electric glass door to fail to open and close.
If this fault occurs, the controller needs to be debugged. If debugging can't make it return to normal, you need to replace the controller. Therefore, it is suggested that you should find professionals when carrying out maintenance and installation.
4. When the induction electric glass door is opened or closed, there is no response when it is electrified.
This situation needs to be detected in the field, because there are many situations where this problem occurs, such as the power supply is plugged in but there is no power supply, which may be caused by the controller crash. Technicians in doorways can detect this problem on the spot and solve the problem in a targeted manner.
Fifth, the remote control problem caused the induction electric glass door to fail to open.
Because of the remote control of the induction electric glass door, it can be unlocked as needed.
Sixth, the induction electric glass door is related to the door action, but it cannot be closed.
The reason is that the sensor has an open signal input, that is, there are interferences in the sensing range of the sensor, such as direct sunlight, moving objects, unstable light sources and so on. It can be detected whether the induction electric glass door cannot be closed because of the interference signal of the sensor by cutting off the signal line of the sensor.
- Related articles
- Yiju Decoration Design Matters needing attention in acceptance of second-hand house decoration in Songjiang District
- What is the telephone number of Jiujiang Zhongjishan River Tiancheng Sales Office?
- The air conditioner is leaking. My 24-year-old mother was electrocuted in stagnant water. Is this the dereliction of duty of the property?
- Where is the international address of Yibin Tietou Sanjiang?
- What's the telephone number of the sales office of Shaoyang Wugang Shanshui Yicheng?
- What should I do if I am a security guard in a property company and I am not allowed to leave?
- What is the Tianjin Rose International Sales Service Hotline in Tianjin?
- How about Jinxiu Pengcheng? OK or not? Is it worth buying?
- Case analysis of property management
- The latest txt complete works of "God beast King Kong"