Job Recruitment Website - Property management - Are the houses and properties in Harbin, Europe, America and Asia sunny? How about heating in winter?

Are the houses and properties in Harbin, Europe, America and Asia sunny? How about heating in winter?

I think it's good. If you think geothermal is more suitable for you, you can change it to floor heating!

If it is the heat source of central heating, it is no problem to change the floor heating, because the heating range provided by the heating company is very wide, and it is generally heated by the secondary water after heat exchange. The temperature is basically above 60 degrees, and floor heating is a low-temperature heating system. High temperature water will seriously affect the service life of floor heating pipes.

The construction of floor heating is very simple, and you need to consider its feasibility when there is no problem with the heat source. For example, the specific situation of your home, the thickness of the ground, the floor and so on. Generally, it is not recommended for users of central heating to modify local heating. Although the heat dissipation effect is good and the space is saved, the pressure is not high because the underground length of the pipeline becomes longer and the frequency of secondary pumps in heat exchange stations in various districts of central heating is generally low. If there is no micro circulating pump, it is likely to cause poor circulation, that is, uneven cold and hot, high room temperature at the near end of the pipeline and low temperature at the far end. Neighbors downstairs will also be affected, which is a potential contradiction and dispute factor.

Regarding the equipment, the floor heating pipe is firstly PE pipe, followed by PPR pipe. Never use aluminum-plastic composite pipe. In many cities, the use of aluminum-plastic pipes is no longer allowed. Under certain conditions, aluminum-plastic pipes will become brittle and have great hidden dangers. In addition to the floor heating pipe, you need a water separator. There are also thermal insulation materials, benzene board, flannel, reflective thermal insulation film and so on. Especially the reflective heat insulation film, without this, you can imagine what kind of mood it would be if the neighbors downstairs found a "ceiling" radiator on their heads. In addition, if the circulation is not smooth, a circulating pump may be needed. Recommended to import, domestic noise and energy consumption are too high.

It is strongly recommended not to cover concrete on the floor heating pipeline during construction. If something goes wrong, you can only use a pickaxe to plane it. Don't say that there is no problem if you do it well. In this respect, we have received a lot of maintenance. 1/4 and 1/6 iron pipes can be broken, not to mention PE and PPR.

As a reminder, it must be pressed after construction to see if there is any leakage. The so-called suppression means that the tap water is connected to the pipeline you just connected. After the pressure reaches a certain level (I don't know the head and frequency of the circulating pump in the residential heat exchange station on your floor, so I can't calculate how much MPA the pressure should be), does the pressure in the pipeline change significantly in a week or so? If yes, carefully check the leakage point. Eliminate hidden dangers.

According to the law, the pipes in households' homes are owned by the state. Residents' unauthorized replacement of heat exchangers or pipes is not allowed by the local heating department, and the losses caused are borne by the residents themselves. If the heating system is affected, it should be removed immediately. Be careful when you do geothermal energy. Everything that goes wrong is your own fault.

Sunshine in Europe, America and Asia

songbei area

Address: Intersection of Xiang 'an North Street and Long Xuan Road, Songbei District, Harbin

Sales address: No.0/07, Zhongyang Street, Daoli District, Harbin

Sales office telephone number 045 1-55550666

The average price is 5000 yuan/square meter.

Price details The average price is 5000 yuan.

Developer Harbin Europe and America Asia World Sunshine Construction and Development Co., Ltd.

The apartment area is 30m2-161m2.

Architectural residence

Property category apartment, multi-storey, high-rise, villa.

The building area is 380,000.

Covers an area of 220,000 square meters

Opening hours: 2065438+April 00 0 1.

Check-in time is 20 10 12 3 1.

Decorative blank

Floor area ratio 1.48

Greening rate 52

The total number of households is 2 100.

Property management company Harbin Europe and America ya property management co., ltd

Property fee 0.55-0.55

Number of parking spaces: 1586 Number of parking spaces: aboveground1274; Underground 312;

Parking space ratio 0.76

Drinking water every household should be equipped with water, electricity and gas meters.

Heating mode central heating

Traffic conditions, take the 216,80, Wal-Mart commuter bus and get off at the Sunshine Sales Office in Europe, America and Asia.

Investor Dalian Europe, America and Asia Group

Dalian Hong Rui Construction Engineering Co., Ltd.

Sales agent Harbin Europe, America and Asia World Sunshine Construction Development Co., Ltd.