Job Recruitment Website - Property management - The first floor is the property house. Is there a problem?

The first floor is the property house. Is there a problem?

There is a problem. The property is an office building. If it is located on the first floor, people will come and go in the office area, which will affect the safety of residents in the building. Property management rooms should be arranged in a location convenient for owners to handle affairs in the property area, and equipped with a guest reception center of about 40 square meters on the ground floor or the second floor. The building where the property management room is located should inform the buyers in advance.

Requirements for the allocation of housing and facilities for residential property equipment

1. monitoring center: each community is equipped with a monitoring center, which is equipped with fire control system, safety monitoring system and elevator communication system. The monitoring center should be arranged on the ground floor, close to the customer service center, with an area of about 30 square meters. Indoor dryness, ventilation and safety. The ground of the monitoring center should be overhead, covered with electrostatic floor, equipped with air conditioner, sand window, mousetrap and fire extinguisher.

2. Power distribution room: The power distribution room should be arranged on the ground floor as far as possible, which is ventilated, dry and safe. The floor should be tiled and the walls should be painted. Install exhaust fan, equipped with fire extinguisher, yellow sand bucket, baffle and screen to prevent rats, sparrows and other animals. It is equipped with a simulation diagram. Insulating rubber pads are laid in front of and behind the ground electric cabinet, equipped with insulating gloves, insulating boots, measuring pens, grounding rods, tool carts and emergency lighting, and the wall is equipped with temperature and humidity devices. If arranged in the basement, waterproof treatment should be done to prevent leakage and air conditioning should be installed.

3. Pump house: The floor of the pump house is tiled, the wall is painted, and the drainage ditch and sewage outlet are covered. There should be no water leakage, and the room should be ventilated, dry and safe. Pipes should be painted with different colors according to their uses, and the flow direction should be indicated.

4. Elevator:

(1) The elevator car in the residential area should have an independent communication device with the monitoring center, that is, three-way or five-way communication, and the wiring should be divided (that is, each elevator room should be equipped with a dedicated line to the monitoring center). If conditions permit, shielded or twisted-pair cables should be used instead of network cables, which are generally four-core cables with an area larger than 1 m2 (according to elevator intercom requirements).

(2) The roof of the computer room should be equipped with thermal insulation device, the interior wall should be painted completely, and the ground should be tiled or painted.

(3) The elevator machine room should be equipped with ventilation and cooling equipment, and the opening of the ventilation device should be at a certain distance from the elevator control panel and the main engine. If the area of the machine room is too small, rainproof devices should be installed in the ventilation holes, the ventilation fan should be a three-phase low-power axial flow fan with a timing controller, and an isolation screen cover should be installed at the tuyere. Conditional installation of air conditioning.

(4) The computer room door should be installed with reliable and firm fire prevention or security door, and the lower part should be provided with a grille to ensure air convection in the computer room.

(5) The elevator machine room should have sufficient lighting brightness and be equipped with a fire extinguisher.

(6) Infrared detection and induction device or door magnetic device should be installed at the door of computer room or machine room, which is connected with the infrared perimeter of residential area to prevent theft.

5. Gatekeeper: The area of the gatehouse is not less than15m2, and the visual effect is good. The roof and wall should be insulated, the indoor floor should be tiled, the wall should be painted and there should be a bathroom. Electric doors, gates, speed brake, cameras and other facilities are installed at the entrance.

6. Garage: The entrance and exit of the garage should be equipped with gates and credit card system, and the slope should be paved with granite as far as possible. The garage floor should be painted and the wall should be painted. Indoor lighting should be controlled by multiple channels. Signs such as height limit and speed limit should be installed at the entrance.

7. Battery car charging equipment: Battery car parking areas should be equipped with charging boxes, one for each household as far as possible. Steel pipes that can lock the wheels of the battery car should be installed below the charging box.

8. Street lamps: Hot zinc tubes are used for street lamps, and the height is controlled at about 3m. LED energy-saving lamps should be installed, and street lamps should be avoided when planting Gao Qiao trees.

9. Property management room: The area of the property management room shall be implemented according to relevant regulations, and it shall be arranged in a position convenient for the owner to handle affairs in the property area, and there is a guest reception center room of about 40 square meters on the first or second floor underground.

10. public electricity metering device: public electricity should be metered as far as possible according to elevator and corridor lighting, street lamps, garages, water supply equipment and other systems.

1 1. air conditioning installation facilities: the reserved position for air conditioning installation should meet the volume requirements of the external machine, and the installation hole is reserved on the wall to install the dropper. The spacing between cooling plates should be no less than 10 cm, which can meet the cooling requirements of air conditioners.