Technical disclosure of fire control construction is urgent. .

A, the basic requirements of the construction site fire prevention

1. The fire control work on the construction site shall be carried out in accordance with relevant national laws and regulations.

2. The person in charge of the construction unit shall be fully responsible for the fire safety work on the construction site, and perform the nine main duties stipulated in Article 19 of the Detailed Rules for the Implementation of People's Republic of China (PRC) Fire Protection Regulations.

3. The construction site should establish and improve the fire inspection system, found that fire hazards, must be eliminated immediately; Hidden dangers that are difficult to eliminate at the moment should be rectified within a time limit by personnel, projects and measures.

4. The construction site should have obvious fire prevention publicity signs. Voluntary firefighters on the construction site shall regularly organize education and training, and store the training materials in office files.

5. When there is a fire or fire on the construction site, it shall immediately report to the public security fire department and organize forces to put out the fire.

6. According to the principle of "four no-misses", after the fire accident, the construction unit and the construction unit shall * * do a good job in site protection and conduct site investigation together with the fire department. Put forward suggestions on the handling of fire accidents and actively implement preventive measures.

7. The construction unit must have fire safety content in the Project Contract signed by the construction project, and do a good job of fire prevention together with the construction unit.

8. When preparing the construction organization design, each unit should meet the requirements of fire control safety in terms of construction general plan, construction method and construction technology.

9. The construction site must be equipped with enough fire-fighting equipment, so that the layout is reasonable. Key parts should be equipped with at least 4 fire extinguishers with obvious fire signs, and designated persons should regularly check, maintain, maintain and update them to ensure that the fire extinguishing equipment is sensitive and effective.

10. The construction site should be equipped with lighting equipment at night, and the forces should be arranged to strengthen the patrol on duty.

1 1. Temporary fire lanes must be set up at the construction site. The width is not less than 3.5m, and the temporary fire lane is clear. It is forbidden to pile up articles and materials or occupy temporary fire lanes.

12. Fire fighting equipment and facilities shall be provided before construction, and outdoor fire hoses and fire hydrant sand boxes shall be laid if possible.

13. When using electricity on the construction site, we should strictly implement the Regulations on Safety Management of Electricity on the Construction Site, strengthen power management and prevent electrical fire. Warehouses, carpentry workshops, paint batching rooms and waterproof workplaces where flammable and combustible materials are stored on the construction site shall not use exposed lamps with high heat intensity.

14. welders and gas welders engaged in electrical equipment installation and electric and gas welding and cutting operations must hold operation certificates and work certificates. Before using fire, flammable and combustible substances should be removed, measures such as isolation should be taken, and fire watchers and fire extinguishing appliances should be equipped. After the operation, you must confirm that there is no fire hazard before you leave. The fire permit is valid on the same day. If the fire place is changed, the procedures for using the fire permit shall be re-handled.

15. The working distance between oxygen bottle and acetylene bottle is not less than 5m, and the working distance between two bottles and open flame is not less than 10m. It is forbidden to store oxygen cylinders and acetylene cylinders in construction projects, and it is forbidden to use liquefied petroleum gas cylinders.

16. The storage and use of building materials shall meet the requirements of fire prevention. The warehouse should be built of incombustible materials. Flammable and explosive articles must have strict fire prevention measures, and should be stored in special warehouses. They should be stored separately by classification, kept ventilated, equipped with fire-fighting equipment, and designated fire prevention leaders to ensure construction safety. It is not allowed to mix paint and vinyl materials in projects or warehouses.

17. Temporary buildings or combustible materials are not allowed to be erected under high-voltage overhead lines.

18. This project is not allowed to be used as a warehouse, and flammable and combustible materials are not allowed to be stored. Combustible materials entering the project due to construction needs shall be restricted according to the project plan, and reliable fire prevention measures shall be taken. Waste should be removed in time.

19. Smoking is strictly prohibited on the construction site. No dormitory shall be set up in construction projects.

20. Without the approval of the security department, electric appliances shall not be used in the construction site and living quarters. It is strictly forbidden to use open flame for heating in the project and open flame for heating in the dormitory.

2 1. When engaged in dangerous operations such as painting or waterproofing, there should be specific fire prevention requirements, and special personnel should be assigned to take care of them when necessary.

22. The setting of living quarters must comply with the fire control regulations. It is forbidden to use combustible materials for erection, and smoking in bed is not allowed in the dormitory. For rooms with more than 20 people, there must be at least two safety doors; When the number of residents exceeds 100, there should be a fire safety passage and evacuation plan.

23. The electricity consumption in the living quarters shall comply with the fire prevention regulations. The use of fire must be approved by the security department, and the fuel used in the canteen must comply with the use regulations. The ignition point and fuel cannot be in the same room. When using, it should be managed by a special person. After the cease-fire, turn off the main switch and check the leakage frequently.