Everyone knows that there are fire protection standards in residential areas. If there is no fire protection standard, the probability of fire will be ve
Residential fire protection regulations?
Everyone knows that there are fire protection standards in residential areas. If there is no fire protection standard, the probability of fire will be ve
Everyone knows that there are fire protection standards in residential areas. If there is no fire protection standard, the probability of fire will be very high. What are the fire protection standards for residential areas? The following are the regulations on fire control in residential areas that I have compiled for you for your reference.
Fire duty system of residential property monitoring command center
A, residential monitoring command center fire control system to implement a 24-hour duty system.
Second, the personnel on duty should be on duty on time, and drinking is prohibited before and during the duty.
Three, the personnel on duty during the duty should stick to their posts, and shall not be late, waiting for work, sleeping; Strictly implement the safety operation procedures of the fire control room, fill in the duty record of the fire control room carefully, and do not shut down the fire control facilities and devices without authorization; Irrelevant personnel are strictly prohibited from entering the fire control room; Non-professionals are strictly forbidden to touch and use the facilities and equipment in the fire control room.
Four, the personnel on duty to do a good job of succession, succession personnel shall not leave without authorization. During the handover, all items in the duty room shall be handed over in detail, and the duty record of the fire control room and the investigation record of fire control implementation shall be carefully checked, so as to clarify the handover matters and fill in the handover record of the fire control room accurately.
5. If the personnel on duty leave their posts without permission during the duty, fail to handle the fire according to the fire disposal procedures, and fail to find, eliminate and report the failure of fire control facilities in time, resulting in a fire accident and serious consequences, they will be investigated for their responsibilities according to relevant laws and regulations.
Fire fighting and fire treatment scheme of community monitoring command center
1. After receiving the fire alarm signal from the fire alarm controller, the personnel on duty in the fire control system of the residential monitoring and command center should determine the specific floor and plane position where the fire alarm occurred through the address code displayed by the alarm host, and immediately notify the relevant responsible personnel at the scene. Relevant persons in charge at the site should carry communication tools and quickly arrive at the alarm point for confirmation.
2. After confirming the fire alarm, the personnel on duty should immediately call the fire alarm number "1 19", report the fire time, fire place, fire object and other site conditions in detail, and notify the competent leader.
Three, after confirming the fire, the personnel on duty should immediately start the fire broadcast, notify the fire floor and adjacent floors to evacuate safely and orderly, and be careful not to cause unnecessary confusion in the building.
Four, the personnel on duty to confirm the fire alarm, should ensure that the alarm linkage is in the state of automatic control, linkage should be manually start all linkage.
Five, in the process of fire disposal, the personnel on duty should monitor the implementation of the fire extinguishing device, pay attention to the development of the fire, and adjust the working state of the device in time.
Six, after the fire disposal is completed or the system confirms the false alarm, the personnel on duty should reset the relevant fire-fighting devices, cooperate with the building fire-fighting facilities management personnel to restore the normal execution of all fire-fighting facilities, and fill in the Fire Control Room Duty Record or the Building Fire-fighting Facilities Fault Handling Record.
Maintenance and management system of fire control facilities in residential buildings
First, the maintenance and management of fire control facilities in residential buildings should be clear about the competent departments and management responsible personnel. Management responsibility personnel must be trained by public security fire control institutions and hold relevant certificates after obtaining fire control professional qualification certificates.
Two, the competent department of building fire control facilities should ensure the investment in the maintenance of building fire control facilities, and establish a technical file for the maintenance of building fire control facilities. Archives mainly include system completion drawings, equipment technical data, operating instructions, commissioning and opening reports, completion reports, completion acceptance forms, maintenance records and other data.
Three, the competent department of building fire control facilities should regularly organize management personnel to inspect, test and maintain the building fire control facilities to ensure that all kinds of facilities and devices are in normal operation. There are three main inspection methods: patrol inspection, single inspection and linkage inspection. Organize inspection at least once a week, and fill in the Inspection Record of Building Fire Protection Facilities; Organize a single inspection at least once a month, and fill in the Record of Single Inspection of Building Fire Protection Facilities; The linkage inspection shall be organized at least once a year, and the Record of Linkage Inspection of Building Fire Protection Facilities shall be filled in. The annual linkage inspection records shall be reported to the local public security fire control institutions for the record before 30 February each year.
Four, building fire control facilities management responsibility personnel found that there is a problem or failure of fire control facilities, must report to the unit safety management personnel, and fill in the "building fire control facilities fault handling record"; If it is necessary to suspend the operation of the system due to failure, maintenance and other reasons, it shall be approved by the person in charge of fire control of the unit. Stop for more than 24 hours, it should be reported to the local public security fire control institutions for the record, and take effective measures to ensure safety. After troubleshooting, it shall be signed by the fire safety manager for approval, and the troubleshooting record shall be filed for future reference. ?
- Previous article:What are the well-known law firms in Shenzhen?
- Next article:Murong Mountain Villa, Chivalrous Scenic Area
- Related articles
- What is the telephone number of the sales department of Huizhou Oriental Sunshine Garden?
- Q 74: what are the fire safety requirements of the isolation belt in the fire zone?
- What are the requirements for foreigners to buy a house in Huzhou?
- How about happy hour eco-tourism co., ltd?
- How to implement the safety production law in property companies of government agencies and units
- Where is Hengshui Harbor Home?
- Where is the address of Luwan, Xinglin, Zhonghai, Xiamen?
- Thirtieth Measures of Gansu Province on Property Management
- Is there a phenomenon of disorderly construction in Xixi Blue Ocean? Is the distance between buildings large enough?
- What mechanisms should health cities, health counties, health towns, health villages and health units establish and improve to consolidate and develop health undertakings?