Job Recruitment Website - Ranking of immigration countries - Construction standard of archives warehouse

Construction standard of archives warehouse

Legal analysis: 1. Archives should be centrally arranged to form a district. 2. The plane layout of the file storage area should be concise and compact. 3. There should be a buffer room at the entrance of the file storage area or the file storage area, and its area should not be less than 6 square meters; . There is no need to set up a buffer room when setting up a special closed veranda. 4. The ground of the archive storage area should be 15mm higher than that outside the reservoir area, and a closed drainage ditch should be set up. 5. Each archive room should have two independent entrances and exits, and collusion or suite layout is not allowed. 6. The clear height of the archive should not be less than 2.60m7, and the layout of archive fittings in the archive should be perpendicular to the wall with windows.

Legal basis: Code for Architectural Design of Archives 4.2 Archives.

4.2. 1 Archives can include paper archives, audio-visual archives, CD-ROM library, microfilm library, master library, special archives, physical archives, book archives and other special carrier archives. , and should be set up or merged according to the level, scale and actual needs of the archives.

4.2.2 Archives should be arranged in a centralized way to form an area. There should be no other rooms in the archive area except the dressing room, and the traffic between other rooms should not pass through the archive area.

4.2.3 The plane layout of the file storage area should be concise and compact.

4.2.4 Buffer room with an area of not less than 6 square meters; Should be set in the file storage area or the entrance of the file warehouse; There is no need to set up a buffer room when setting up a dedicated closed veranda.

4.2.5 The ground of the archive storage area should be 15mm higher than that outside the storage area, and a closed drainage ditch should be set.

4.2.6 Each archive room should have two independent entrances and exits, which are not suitable for collusion or suite layout.

4.2.7 The clear height of archives shall not be less than 2.60m.

4.2.8 The file fittings in the archives room should be arranged in rows perpendicular to the wall with windows. The passage between file accessories should correspond to the lighting window of the external wall, and the opening direction of the ventilation hole of the pipeline should correspond to the absence of the window.