Technical Specification for Video Access Control Alarm System of Shenzhen Rental House Chapter II System Technical Scheme
2. 1. 1 system classification According to the local economic development, social and cultural conditions, combined with the investment scale and security management requirements, the video entrance guard alarm system for rental houses in Shenzhen is divided into basic, standard and advanced types.
2. 1.2 system The video entrance guard alarm system of Shenzhen rental house mainly includes: entrance guard system, video monitoring system, alarm system and management platform (monitoring center) of Shenzhen rental house video entrance guard alarm system. If possible, you can choose to add building intercom, electronic patrol, parking lot management, perimeter prevention and portrait recognition system.
2. 1.3 Configuration Requirements See table 2.2. 1 and public security networking architecture for the basic, standard and advanced configuration and requirements of Shenzhen rental house video entrance guard alarm system.
Shenzhen rental housing standard and advanced video access control alarm system should adopt networking architecture, and the local networking of villages in the city should adopt VPN private network or Internet. When accessing the public security information network, it must be accessed through the security isolation platform according to the network security requirements of the Ministry of Public Security, and the access plan must be reported to the provincial public security department and the Ministry of Public Security for approval. The architecture of public security network is shown in the figure.
2.2.2 Non-network architecture
The basic type of video access control alarm system in Shenzhen rental house can choose non-networked architecture or VPN network architecture established in this village, as shown in the figure. 2.3. 1 access control system requirements
The access control system shall, according to the structural layout of the building and the management requirements of safety precautions, classify the access levels of various entrances and exits that need to be controlled according to different access objects, and implement access control and management. The card reader should be able to identify the Residence Permit and the Second Generation Identity Card; The system should be connected with GIS system, video monitoring system and alarm system; Audible and visual alarm should be set at the door of the rental house. When the door is not working normally or unlocked, it should be able to give an audible and visual alarm, and the relevant technical requirements should comply with the Technical Requirements for Access Control System (GA/T394-2002).
The entrance and exit control of personnel escape exits shall comply with the relevant provisions of Clause 9.0. 1 in Clause 2 of GB50396-2007.
For the built access control system, the card reading equipment that can read the information of "residence permit" and "second-generation ID card" should be replaced.
Monitoring system requirements
The construction of video surveillance system should follow the relevant national industry standards and government norms. According to the actual situation, N(N≥ 1) fixed cameras (guns) are installed at the entrance to be controlled, and the entrance to be controlled and related areas are fixedly monitored. If conditions permit, a spherical camera can be appropriately added for panoramic monitoring. When the image is connected to the local monitoring center, an interface for uploading relevant information should be reserved. The functional requirements are as follows:
Video monitoring system should be combined with electronic map.
On/off, automatically start the video recording system and save the image.
Automatically start the video recording system when giving an alarm and save the image.
According to the actual needs, the portrait snapshot function is added to save the image.
Video recording should be at least 15 days.
Video data can be queried in time.
Video information can be queried through on/off events.
Video data can be queried according to alarm events.
Alarm system requirements
The construction of alarm system should conform to the relevant national industry standards and relevant government norms. The information format and transmission protocol of alarm signal refer to the relevant requirements in Information Format and Protocol of Serial Data Interface of Alarm Transmission System (GA/T 379.1~ 379.6438+00-2002). The alarm system shall have the following functions:
It should be able to receive the alarm information sent by the alarm source in real time, and distribute the alarm information to the corresponding user terminal or system equipment in time according to the alarm processing plan.
When the alarm occurs, the system should be able to automatically trigger the image re-inspection or the sound synthesis equipment to re-inspect the alarm through a preset way, and trigger the video recording equipment to record and store.
Trigger and start video display and recording in the local monitoring center.
The response time of direct linkage should be ≤ 4 s.
Alarm image pre-recording time ≥ 10s.
The monitoring center should be able to record all alarm information, and output, print and upload it to the designated place.
The alarm system should be connected with GIS system and video monitoring system.
2.4 Platform construction requirements
The networking integration platform of Shenzhen rental house video access alarm system is managed by the Municipal Public Security Bureau in accordance with the requirements of Guangdong Social Security Video Surveillance System Monitoring Center Platform Construction Specification, which realizes the unified management and exchange of information collected by Shenzhen rental house video access alarm system, thus promoting the development of Shenzhen rental house video access alarm system from "single point" and "region" to "networking". At the same time, realize the integration of the second and third types of electronic prevention and control resources in Shenzhen, further promote the application of "residence permit" in Shenzhen, meet the application needs of relevant industry departments in Shenzhen, and provide basic platform support for comprehensive management of social security and dynamic control of statistical data in Shenzhen.
The networked integrated platform of video entrance guard alarm system in Shenzhen rental house should be able to detect and control the running state of each monitoring center subsystem in real time, and can remotely store and display the running state and data information of the system. Each monitoring center subsystem is relatively independent, and the failure of the networked integrated platform should not affect its normal operation.
The construction of the monitoring center where the video entrance guard alarm system integrated platform of Shenzhen rental house is located should meet the requirements of Technical Specification for Safety Prevention Engineering (GB 50348-2004) and General Technical Requirements for Residential Area Safety Prevention System (GB/T 2 174 1-2008).
2.5 Other requirements
2.5. 1 data * * *
The Municipal Public Security Bureau is responsible for building the basic information base of the video entrance guard alarm system for rental houses in Shenzhen, and realizing the association and data sharing with the eight resource databases, intelligence integrated application system, police integrated information system, 1 10 alarm processing system, police geographic information system (GIS), motor vehicle/driver management system and comparison control system of Shenzhen Public Security Golden Shield Project.
other
The electromagnetic compatibility, lightning protection and grounding, standby power supply and engineering construction specifications of the system shall comply with or refer to the relevant provisions of Technical Requirements for Lightning Wave Protection of Safety Protection Systems (GA 670-2006) and Technical Specifications for Safety Protection Engineering (GB 50348-2004).
The installation site of front-end equipment of video entrance guard alarm system in Shenzhen rental house should be equipped with auxiliary light source or infrared camera according to the actual situation to ensure that regional monitoring and image acquisition meet the standard requirements.
For the construction requirements of building intercom, electronic patrol, parking lot management, perimeter prevention, portrait recognition, etc. integrated with video entrance guard alarm system in Shenzhen rental house, please refer to General Technical Requirements for Security System in Residential Quarters (GB/T 2 174 1-2008), Technical Specification for Security Engineering (GB 50348-2004) and "Security Engineering". Construction of relevant standards such as Technical Requirements for Electronic Patrol System (GA/T 644-2006), Technical Requirements for Access Control System (GA/T 394-2002) and Technical Requirements for Intrusion Alarm System (GA/T 368-200 1).
Overall architecture
- Related articles
- The role of third-party organizations
- What kind of housing is Wuxi Nanhu Home?
- Is Tongjing New Village a demolition house?
- What time does Handan Yongmei Garden open?
- How many years is the property right of Jingzhou Jiujiu Manor Villa?
- Jiaoda Road 100 is still being demolished.
- Zhuzhou self-driving Hainan Raiders Latest Zhuzhou self-driving Hainan Raiders
- Shenzhen subway operation company
- Is Chengdu Taishengxin Tiandi worth buying?
- Several problems about property