In the study, work and life on weekdays, emergencies occur from time to time. In order to avoid causing huge losses and harm, emergency plans are often made in advance according to specific conditions. What problems should be paid attention to in compiling emergency plan? The following is my model essay on the emergency plan for residential property elevators. Welcome to reading. I hope you will like it.

Emergency Plan for Residential Property Elevator 1 (1) When the elevator breaks down, the supervisor shall immediately notify the person in charge of the engineering department and the maintenance personnel, and the maintenance personnel or rescue personnel of the engineering department may try to rescue the trapped passengers first according to different situations.

(2) Rescue procedures for trapped elevator personnel:

1. Rescuers can get in touch with trapped passengers through walkie-talkies or mobile phones. Be sure to ask passengers to stay calm and wait for rescue. Trapped passengers are not allowed to stick any part of their bodies out of the car. If the door is in a half-open state, rescuers should try to completely close the door to prevent accidents.

2. Accurately judge the position of the car and prepare for rescue. We should judge the position of the car according to the floor indicator light, PC display, floor selector crossbar or door opening, and then try to rescue the passengers.

(3) Rescue steps:

1. Rescue steps when the car stops near the elevator entrance:

① Turn off the power switch of the machine room;

② Open the outer door with a special lock key;

③ Open the car door slowly by manpower at the top of the car;

(4) assist passengers to leave the carriage;

⑤ Close the hall door again.

2, the car away from the elevator rescue steps:

① Enter the computer room and turn off the fault potential power switch;

(2) Remove the motor tail shaft end cover and press the knob seat and knob;

(3) Rescuers hold the handle hard, and another rescuer holds the brake release lever, gently pry open the brake, pay attention to the plane sign, and make the car gradually move closer to the hall door;

(4) Emergency treatment of abnormal situations: When abnormal situations occur in the elevator, passengers should keep calm and clear-headed to seek a safer solution.

(5) Disposal measures in case of fire:

① When there is a fire on the floor, the personnel on duty in the elevator machine room should immediately try to press the "fire switch" to make the elevator enter the reverse operation state; After the elevator runs to the base station, guide the passengers to leave the car quickly, and inform the engineering department by telephone, and dial 1 19 at the same time.

(2) When the hoistway or car is turned off, immediately stop the elevator and guide the passengers to leave. After cutting off the power supply, use dry powder fire extinguisher or 12 1 1 fire extinguisher to extinguish the fire; And call the engineering department; If the fire is fierce, you should call the police immediately 1 19 to ensure the safety of people and property in the building.

(6) elevator water treatment measures:

(1) When the tunnel is flooded, the elevator should stop above the second floor;

(2) When the floor is flooded, stop the elevator at the flooded upper floor, then turn off the main power switch and immediately organize personnel to block the water source. After the water source is blocked, it should be dehumidified, such as hot air drying.

(3) Finally, test the insulation resistance with a shaking table. After reaching the standard, you can try the ladder. After the test ladder is normal, it can be put into normal use.

Elevator emergency plan for residential property 2 As a means of transportation for people to get up and down floors, elevators should pay more attention to safety issues. In order to ensure the safe, effective and reliable operation of elevator equipment, reduce the impact of accidents and avoid personal injury accidents, Xingtai Elevator formulates this plan. The plan is divided into three stages.

A, accident report disposal procedures

1. When receiving the accident report, the personnel on duty in the engineering department should know the following information from the reporter: the location of the faulty elevator, whether it is trapped or not, which floor it is trapped on, and make records.

2. The personnel on duty in the engineering department shall verify whether the reception is correct to the monitoring room by telephone.

3. After confirming the situation, the personnel on duty in the engineering department immediately rushed to the scene and informed the maintenance unit to arrive at the scene immediately.

4. Personnel with elevator operation qualification should bring the keys of elevator machine room, elevator landing doors, communication tools and maintenance tools to the site for treatment. If necessary, additional personnel will be sent to assist in the duty.

Second, the elevator fault handling procedures

Two fault handlers (1, Party A and Party B) arrive at the elevator machine room and the elevator car floor respectively.

2. Answer: First cut off the main power supply of the elevator, but the car lighting must be maintained. Get in touch with the trapped person through the direct dial telephone in the elevator room, and tell the trapped person to wait for rescue and not to try to leave by himself.

3.b: Use the elevator landing door key to open the elevator landing door for about 30-40 cm, and observe the position of the elevator car.

4. If the car is located within 600cm of the flat floor, the trapped person can leave smoothly, and the landing door can be directly opened to assist the passengers to leave.

5. If the trapped person cannot leave smoothly when the car is not in the above position, it is necessary to manually level the floor according to the following steps before releasing the passengers.

(1) first calm the passengers' emotions, inform them that the rescue operation is in progress, and (1) let them wait patiently for the rescue.

(2) Remove the protective cover at the end of the elevator traction motor and put the special rotating handwheel on the motor shaft.

(3) Remove the cover of the brake electromagnet and fasten the brake release handle on the brake mechanism.

(4) One person grasps the rotating handwheel, and the other person slowly presses the brake release handle to release the brake mechanism. When the brake mechanism is released, slowly turn the handwheel and use the car to go up or down (clockwise, the car goes up. Turn the car counterclockwise). Stop turning the rotating handwheel and reset the braking device. It must be noted that due to the unbalanced weight of the car, you should be very careful and slow when releasing the brake device manually when turning to prevent excessive acceleration from getting out of control.

(5) Rotating lifting mechanism. When the leveling mark line on the wire rope is aligned with the leveling mark of the elevator, it means that the elevator car has been leveled. At this point, the braking mechanism should be restored.

(6) Open the elevator landing door with the elevator landing door key, and close the landing door after releasing the passengers.

6, by the maintenance unit to conduct a comprehensive inspection of the elevator, eliminate hidden dangers before resuming power supply operation.

Post-event handling program of elevator fault

1, after the failure handling is completed, the handling personnel shall report the handling process and equipment status to the engineering manager in time.

2. Analyze the reasons for the failure. Submit a written report to the engineering manager for equipment accidents caused by improper use or maintenance.

3, do a good job of fault registration of equipment files.

Emergency Plan for Residential Property Elevator 3 I. Emergency Plan for People Trapped in the Elevator

1. When receiving the owner's alarm or finding passengers trapped in the elevator, it shall immediately notify the security fire control room and record the time of receiving the report and finding it.

2. After receiving the report, the security fire control room should, on the one hand, know the location, the number of people trapped and the elevator floor through the monitoring system or walkie-talkie, on the other hand, report to the security manager through the walkie-talkie and contact the maintenance unit for rescue.

3. After receiving the report, the manager of the security department immediately came to the scene in person or sent personnel to get in touch with the trapped passengers to comfort them and ask them to stay calm and wait patiently for rescue. Especially when the trapped passengers are frightened or very impatient and try to escape by taking extraordinary measures such as prying the door, they should be patiently warned not to panic and be impatient, and not to take unnecessary actions blindly, so as not to enlarge the fault and cause danger. Note: During this process, no one should be left at the scene. Keep in touch with the trapped people, keep abreast of their mood and health, and report the situation to the general manager or the leader on duty in time.

4. After receiving the report, the manager of the maintenance unit or the personnel on duty should immediately send someone to the scene for rescue, and at the same time call the elevator maintenance company for emergency repair.

5. If the maintenance unit and elevator maintenance company are unable to rescue or can't rescue in a short time, they should ask the public security department or the fire department for help as appropriate (the reasons and circumstances for help should be explained). Before asking the public security fire department for help, you should get the consent of the general manager or the leader on duty.

6. In the process of rescue, if anyone (especially the elderly or children) among the trapped passengers is found fainting or comatose, the medical staff should be immediately notified to be present, so that the trapped passengers can be rescued after being rescued.

7. After the trapped person is rescued, the manager of the security department or the foreman on duty should immediately express condolences to him, understand his physical condition and needs, and ask him to provide his name, address, contact number and the reason for coming to the community. If the trapped person does not cooperate to leave, it shall be recorded and filed.

8. After the trapped person is rescued, please ask the elevator maintenance company to find out the cause of the fault immediately, and the normal operation can be resumed after the repair.

9. The manager of the security department or the foreman on duty shall make a detailed record of the incident, including the time when the report was received, the time when the security and maintenance personnel arrived at the scene, the notice and arrival time of the elevator maintenance company, the rescue time of the trapped personnel, the basic situation of the trapped personnel, and the time when the elevator resumed normal operation. If there are public security, fire fighting and medical personnel present, the arrival and departure time and vehicle number should also be recorded separately; If an injured person is trapped, record the situation of the injured person and the hospital he was sent to.

10. The management personnel or personnel on duty of the maintenance unit shall record the time, cause, rescue method and repair time of the fault in detail.

Second, the emergency plan for sudden power failure

1. In the case of receiving the power outage notice, the management department should inform every household and merchant of the power outage line, area, time, elevator use and safety precautions in advance, and issue the power outage notice at the main entrances and exits; At the same time, the maintenance unit should do the emergency work before the power failure.

2. If there is a sudden power outage without receiving any notice, the maintenance unit shall immediately confirm whether it is an internal fault power outage or an external power outage. If it is an internal fault power failure, immediately send someone to find the reason and take measures to prevent the fault from expanding; If it is an external power outage, on the one hand, it is necessary to prevent accidents caused by sudden calls, on the other hand, it is necessary to call the Power Bureau to inquire about the power outage, know when to restore power supply, and inform the management and operation department of the information.

3. The security department will immediately send people to each floor to check the elevator operation together with the maintenance unit. When the elevator stops, it will be rescued immediately according to the emergency plan of the trapped elevator personnel.

4. Arrange employees to the main entrance and exit of the community and the elevator hall to maintain order. Security guards should strengthen security measures to prevent people from creating chaos, fish in troubled waters, and close the door when necessary.

6. Preventive measures for sudden power failure:

1) The maintenance unit shall regularly check the emergency lighting and emergency broadcasting system to ensure normal operation.

2) The management department should remind office residents and merchants to prepare some emergency lights or candles to prevent power failure.

3) In addition to flashlights for patrol and maintenance, security departments and maintenance units should also be equipped with portable emergency lighting, which should be charged and maintained at any time to keep it in good condition.

Three. Emergency treatment in case of fire.

1. Contact the fire department in time and report to relevant leaders.

2. Press the "fire button" of the elevator with fire fighting function to carry out fire fighting.

The elevator enters the fire-fighting operation state for the use of firefighters; For elevators without fire fighting function, immediately drive the elevator to the first floor and cut off the power supply or park the elevator on the floor where the fire has not spread. After warning the passengers in the car to stay calm, organize and guide the passengers to leave the car, evacuate along the safe passage, put the elevator in a "stop running" state, close the hall door and car door by hand, and cut off the main power supply of the elevator.

[13] When there is a fire in the shaft or car, immediately stop the ladder to guide the passengers to evacuate, cut off the power supply and put out the fire with a fire extinguisher.

4. When there is a fire in the elevator of * * * shaft, immediately park the remaining elevators that are not on fire away from the fire spreading area, or hand them over to firefighters for fire fighting.

5. When there is a fire in the adjacent building, you should also stop using the ladder to avoid the trouble caused by power failure due to the fire.

4. If there is an earthquake.

According to the emergency measures issued by the local people's government to the residents in the forecast area, decide whether and when to stop the elevator operation.

1. For earthquakes with large magnitude and intensity, they occur suddenly without imminent earthquake prediction before the earthquake. Once the elevator stops nearby, passengers leave the car and escape nearby. If passengers are trapped in the car, don't escape by yourself, stay calm and wait for rescue.

3. After the earthquake, the elevator should be checked and put into trial operation, and it can be used again after it is normal. When the magnitude is below 4 and the intensity is below 6, the elevator should be inspected: whether there is any abnormality in the power supply system; Whether the hoistway, guide rail and car are abnormal; Run the whole journey up and down at the maintenance speed. If any abnormality is found, stop the elevator immediately, and stop the elevator in the reverse direction at the highest station, which will be inspected and maintained by professionals. There is no abnormality in the whole process, and it can only be put into use after repeated trial operation.

5. When wet water appears.

In case of typhoon, thunderstorm, flood and other bad weather, preventive measures should be taken, elevator inspection should be strengthened, and doors and windows of the computer room should be closed. The main roof or doors and windows of the elevator machine room leak rain and water; Because the waterproof layer of the building is not handled well, the bottom pit leaks water; When the leakage of heating, water supply and drainage pipes, fire hydrants and domestic water causes wet water accidents in the elevator, in addition to blocking the building facilities, emergency measures should also be taken: when a small amount of water or seepage is found in the pit, the elevator should be parked on the second floor or above, stop running and disconnect the main power supply.

1. When the floor is flooded, and the shaft or pit is flooded, the car should stop at the upper second floor of the entrance floor station, and the elevator should stop and power off to prevent the car from being flooded.

4. When there is a lot of water in the pit or the machine room, stop the ladder immediately and turn off the main power switch to prevent accidents such as short circuit and electric shock.

[14] When wet water occurs, the source of water leakage should be cut off quickly to prevent electrical equipment from entering water or less.

4. Wet water elevators should be dehumidified, such as wiping, hot air drying, natural ventilation and pipeline replacement. After confirming that the wet water is removed, the insulation resistance meets the requirements and the test ladder is normal, it can be put into operation. For the elevator controlled by microcomputer, check it carefully to avoid burning the circuit board.

5. After the elevator resumes operation, fill in the wet water inspection report in detail, and record the reasons, treatment methods and preventive measures of wet water clearly and file them.

Emergency plan for residential property elevator 4 1. After receiving the power outage notice, the management and operation department shall inform the residents and merchants of the power outage line, area, time, elevator use and safety precautions in advance, and issue power outage notices at the main entrances and exits; At the same time, the engineering materials department should do the emergency work before the power failure.

2. In case of sudden power failure without receiving any notice, the Engineering Materials Department shall immediately confirm whether it is an internal fault power failure or an external power failure. If it is an internal fault power failure, immediately send someone to find the reason and take measures to prevent the fault from expanding; In case of external power failure, on the one hand, it is necessary to prevent accidents caused by sudden calls, on the other hand, it is necessary to call the Power Bureau to inquire about the power failure, know when to restore power supply, and inform the management and operation department of the learned situation.

3, the security department immediately in conjunction with the project ministry of materials and equipment sent separately to the floors to check the elevator operation, found that the elevator shut people immediately according to the elevator trapped emergency rescue plan.

4. The management and operation department will immediately notify the residents and merchants of the power outage, and issue power outage notices at the main entrances and exits. When necessary, the emergency broadcast system will be activated to inform residents and ask them to remain calm and take preventive measures.

5. In case of sudden power failure, when the mall is open at night, the security department should assist the mall to maintain good order, guide the merchants to use emergency lighting, candles and other backup lighting to evacuate customers, and pay attention to fire prevention to prevent fire.

6. Arrange employees to the main entrance and exit of the community and the elevator hall to maintain order. Security guards should strengthen security measures to prevent people from creating chaos, fish in troubled waters, and close the door when necessary.

7. Send people to guard the office and duty room, patiently receive inquiries from residents and merchants, do a good job of explanation and guidance, and prevent conflicts with residents and merchants.

8. Record the time, causes, countermeasures and losses caused by the power failure accident in detail.

9. Preventive measures for sudden power failure:

1) ministry of materials and equipment shall regularly check the emergency lighting and emergency broadcasting system to ensure normal operation.

2) The management and operation department should remind office residents and merchants to prepare some emergency lights or candles to prevent power failure.

3) In addition to flashlights, the security department and the engineering materials department should also be equipped with portable emergency lighting for patrol and maintenance, and they should be charged and maintained frequently to keep them in good condition.

;